Case Western Reserve University School of Graduate Studies
Quantitative Evaluation of Emerging Cancer Imaging Agents
Abstract
dc:descriptionThe goal of this work is to create software platforms for evaluation of two imaging agents. One is for a fibrin-fibronectin targeting probe CREKA-Gd applied to detect breast cancer metastases in whole mouse body, and the other one is for a protease-activated probe 6qcNIR designed for better visualization of the surgical margins of keratinocyte carcinomas. Both platforms include imaging protocols and analysis software to evaluate these promising molecular approaches at the cellular level.For evaluation of CREKA-Gd, 3D cryo-imaging that sections and images a whole mouse and provides microscopic fluorescent and color images was utilized to generate ground truth for GFP-labeled metastases. Convolutional neural network (CNN)-based algorithms were utilized for segmenting GFP-labeled breast cancer metastases and organs of interest to quantify the metastases distribution. Metastases segmentation software included three steps: candidate segmentation, CNN-based candidate classification, semi-automatic correction, reducing human intervention time from >12 hours to ~2 hours. The algorithm was successfully applied for segmenting pancreatic metastases, demonstrating generalizability. For multi-organ segmentation, 2D U-Net and 3D U-Net were compared. With 63 mice for training, 2D U-Net had the best performance with median Dice score >0.9 for all organs except bladder. Deep learning organ segmentation achieved human segmentation accuracy, reduced inter-observer differences, and cut manual intervention time from ~2 hours to 25 minutes for editing. Fluorescent imaging using 6qcNIR allowed 100% tumor margin assessment by generating en face images that correlate with histology and may be used to overcome the limitations of conventional bread-loaf histology. For evaluation of 6qcNIR, imaging was done with an inverted, flying-spot fluorescence scanner that reduces scattering. We developed a “puzzle-fit” software to correlate the fluorescent images with histology with spatial accuracy of ∼500μm. “Puzzle-fit” involved image segmentation, fiducial-based registration, and non-rigid free-form deformation on fluorescence images, corresponding color images, “bread-loafed” tissue images, hematoxylin and eosin (H&E)-stained slides, and pathological annotations. Clinicians were effectively trained to read fluorescent images within 15 minutes with reliability and confidence resulting in sensitivities of 62-78% and specificities of 92-97%.Analysis methods and software demonstrated in the thesis should be applicable to a wide range of studies of cancer, imaging agents and theranostics.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Liu, Yiqiao
- Advisor dc:contributor.advisor
-
- Wilson, David
- Chair dc:contributor.committeechair
-
- Tiwari, Pallavi
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case163897732640668