IMAGING WITH NANOBUBBLE ULTRASOUND-CONTRAST AGENTS

Abstract

dc:description

Ultrasound (US) is safe and low-cost relative to other imaging technologies, making it an increasingly popular diagnostic modality. US contrast is often limited by relatively low differences in acoustic impedance in the body, necessitating the use of contrast agents like microbubbles (MBs; ~1-10 µm diameter) which are intravenously injected and used to compensate for low contrast in conventional B-mode US imaging. The large size of MBs, however, limits their applications to the blood pool. In many diseases, including cancer, information beyond the blood pool is needed for diagnosis and staging. For instance, in many cancers (e.g. prostate, mammary, ovarian etc.), tumors are characterized by high vascular permeability and low lymphatic drainage, which increases the potential for enhanced permeability and retention (EPR) of macromolecules (~200 nm). When present, EPR leads to the tumor-localized accumulation of nano-agents. Nanobubbles (NBs) are new-age submicron bubble agents (100-500 nm diameter) capable of extravasation beyond the vascular network while providing enhanced US contrast similar to MBs. Recently, our group showed that active targeting of NBs to prostate specific membrane antigen (PSMA) rapidly and selectively enhances tumor accumulation and retention. These processes were visualized in real-time with clinical US. This project established NBs as a sensitive detection tool in the diagnosis of PSMA-positive prostate cancer due to localized NB accumulation, reduced diameter and higher number density (NBs per volume) of NBs compared to MBs of similar composition. Together, these points enable: 1) contrast visualization of small capillaries with higher fidelity, and 2) imaging of extravascular cellular targets reached via extravasation of NBs in leaky blood vessels while employing 3) a safe and widely accessible imaging modality. Together, contrast enhanced ultrasound (CEUS) using NBs (NB-CEUS) is a detection method with high biocompatibility and high safety profile. Despite these benefits, NB use in US imaging has yet to reach its full potential. US systems are optimized for MB use leading to potentially limited contrast enhancement and elevated rates of NB destruction. Additionally, extravasation results in a time-dependent loss of vessel visibility as contrast increases beyond the vascular network. As such, review of such videos is time-consuming and requires close supervision to determine the presence of EPR. Suboptimal imaging parameters and extensive imaging and analysis periods are significant burdens that directly impede clinical implementation of NB US contrast agents. There is therefore a need to produce an imaging suite using appropriate US imaging parameters (pressure and frequency) and develop improved methods for assessing vascularization and perfusion of tissue without significant burdens on time and cost. Such a tool could be used not only for tumors, but for all diseases involving pathologically permeable vasculature. With this goal in mind, the objective of this thesis is to work toward development of an optimized, real-time method for evaluating vascular permeability over the entire tumor using novel NB-CEUS techniques.This work builds upon dynamic CEUS protocols used clinically with MBs. NBs, which are 100-500 nm in diameter, are approximately 10x smaller than MBs and have been shown to extravasate into the tumor interstitium. To reach the final objective of this work, NB enhancement under a fully characterized commercially available US system must be studied. To this aim, in vitro studies concerning NB backscatter and decay based on pressure and frequency US parameters were first performed. This involved evaluating changes in NB-CEUS intensity and frequency data for establishing high contrast, low decay signal from NBs. To the second aim, we proposed to develop NB-CEUS mapping to decouple localized agent accumulation which occurs in the presence of EPR. The method enabled accurate separation of extravasated NBs located in deep tumor tissue from intravascular NBs. Visualization of the vascular network and heterogeneity of the tumor core was achieved in tandem. Currently there is no clinical imaging method for distinguishing between tumor-accumulated (slow/stationary) NBs and intravascular (flowing) NBs with sufficient sensitivity. Using prostate cancer as a testcase, we improved the delineation of prostate tumors through the separation of stationary from moving NB agents when perfused from the vasculature of solid tumors. The work in this thesis represents a new approach for CEUS using NBs to characterize tumoral microenvironment characteristics like vascular permeability. Overall, the successful implementation of this work would directly address the need for a rapid and accurate assessment of the heterogeneous physiology of pathologically leaky tissue.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wegierak, Dana
Advisor dc:contributor.advisor
  • Exner, Agata
Chair dc:contributor.committeechair
  • Ma, Dan

Subjects

dc:subject × 24

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Wegierak, Dana. IMAGING WITH NANOBUBBLE ULTRASOUND-CONTRAST AGENTS. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2024. http://rave.ohiolink.edu/etdc/view?acc_num=case1712225043131766