Case Western Reserve University School of Graduate Studies
Vision-based Force Estimation Using Deformable Grippers
Abstract
dc:descriptionSensing tool-tissue interaction forces and providing haptic feedback can enhance surgeon performance in Robotic Minimally Invasive Surgery (RMIS). Two major sensing techniques in RMIS are direct sensing and indirect sensing. Direct sensing relies on sensor measurement approaches. By deploying sensors directly on the surgical instruments, direct sensing has the advantage of high accuracy and reliability while restricting the sensor's size and biocompatibility. Current indirect sensing methods rely on tracking visual deformation of the environment or the tool or measuring motor torques. They can be more biocompatible and cost-efficient but trade off sensing accuracy and reliability. One promising approach to indirect force sensing has been to use data-driven approaches such as neural networks. One promising approach to indirect force sensing has been to use data-driven approaches such as Neural Network (NN). However, these data-driven models require significant amounts of labeled training data, which can be costly or infeasible to acquire, especially in vivo. Furthermore, they can fail to generalize when tracking visual deformation in complex environments. To address data-driven models' data-reliance problems of low capability in complex environments, we proposed a new Vision-based Force Estimation System (VFES) using a model-based deformable inverse Finite Element Analysis (FEA) approach to conduct force estimation in real-time. Our method requires no training data but rather takes deformation data captured by a structure light camera as input for the inverse FEA simulation in Simulation Open Framework Architecture (SOFA). We demonstrate that our system can achieve high accuracy under static scenarios with a RMSE less than 0.18 N and an NRMSD of 4.25 %. Through dynamic evaluations, our system was validated to have less than 0.66 N and a NRMSD under 15 % when moving frequency of the observed object is less than 2 Hz. We also test the bandwidth of our system to show its dynamic capability, showing the cutoff of our system for magnitude response is 2.5 Hz and 4.0 Hz for phase response.
Degree
thesis:*- Name thesis:degree_name
- Master of Sciences
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- EMC - Mechanical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zuo, Kaiwen
- Advisors dc:contributor.advisor
-
- Chua, Zonghe
- Daltorio, Kathryn
- Chair dc:contributor.committeechair
-
- Taylor, Brian
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1718120033936051