Back to search

Case Western Reserve University School of Graduate Studies

Bioreagent-enhanced Dielectric Blood Coagulometry for Assessment of Hemostatic Defects

Abstract

dc:description

Timely characterization of the hemostatic system at the point-of-care/point-of-injury (POC/POI) is clinically important in traumatically injured and critically ill patients to guide therapeutic interventions and improve survival outcomes. This work advances the development of a microfluidic dielectric sensor, termed ClotChip, as a platform technology for POC/POI assessment of whole blood coagulation by enhancing its readout characteristics to precisely identify a range of blood coagulation disorders, including dysfunctions in fibrin formation and fibrinolysis. Specifically, two new distinct readout parameters in the ClotChip readout curve, namely, lysis time (LT) and maximum lysis rate (MLR) are identified and shown to be sensitive to the fibrinolytic status in whole blood. LT identifies the time that it takes from the onset of coagulation for the fibrin clot to mostly dissolve in the blood sample during fibrinolysis, whereas MLR captures the rate of fibrin clot lysis. A third new parameter, Smax, is also identified that represents the maximum permittivity slope and is shown to be sensitive to fibrin-polymerization defects during clot formation. These findings are validated through correlative measurements with rotational thromboelastometry (ROTEM) – a clinical, viscoelastic-based, global assay of blood coagulation.This work also includes the development of next-generation miniaturized dielectric coagulometry featuring multiple channels with bioreagent-functionalized electrodes that uniquely and specifically elicit differential responses from the multifactorial process of blood coagulation. Specifically, a microfluidic sensor is developed with physisorption of tissue factor and aprotinin on the electrode surfaces to probe the fibrinolytic function. The dual-coated microsensor can detect the hemostatic rescue in the hyperfibrinolytic profile of whole blood coagulation induced by tissue plasminogen activator as well as the hemostatic dysfunction due to concurrent platelet count deficits in the blood sample, thus featuring enhanced ability in evaluating complex, combinatorial coagulation disorders.Finally, this work explores the use of ClotChip for POC analysis of coagulation profile in sepsis and COVID-19 patients. Specialized bioreagents are used with a handheld ClotChip device, resulting in substantial increase in its diagnostic sensitivity. Taken together, these efforts advance the ClotChip technology and the technique of miniaturized dielectric blood coagulometry as a diagnostic platform for rapid POC/POI assessment of a broad range of hemostatic defects.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
EECS - Electrical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pourang, Sina
Advisor dc:contributor.advisor
  • Mohseni, Pedram

Subjects

dc:subject × 13

Rights

dc:rights
Statement dc:rights
  • restricted--full text unavailable until 2028-01-17
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Pourang, Sina. Bioreagent-enhanced Dielectric Blood Coagulometry for Assessment of Hemostatic Defects. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2025. http://rave.ohiolink.edu/etdc/view?acc_num=case1733316822570767