Back to search

Case Western Reserve University School of Graduate Studies

Susceptibility-based Magnetic Resonance Imaging Biomarkers for the Diagnosis of Multiple Sclerosis

Abstract

dc:description

Background: Misdiagnosis of MS and diagnostic delays occur due to atypical clinical/radiological manifestations, misapplication of the diagnostic criteria, and misinterpretation of MRI findings. As radiological correlates of histopathologic findings associated with MS lesions, CVS and PRL may improve the diagnostic process.Methods: Chapter 1 describes the evolution of MS diagnostic criteria. Chapter 2 is a systematic review and meta-analysis summarizing the diagnostic performance of abbreviated CVS methods and PRL for MS. Chapters 3 and 4 are based on the CAVS-MS pilot data, a multi-center study enrolling individuals with consideration of MS due to clinical/imaging findings. Chapter 3 describes the performance of Select 3 and Select 6 for a diagnosis of MS in those with available CSF testing (n=53, 24 with MS), while Chapter 4 describes the diagnostic performance of CVS and PRL integration for MS (n=78, 37 with MS). Chapter 5 is a viewpoint highlighting 2024 McDonald criteria updates.Results: The inclusion of MRI and CSF findings into the MS diagnostic algorithm enabled an earlier and more accurate MS diagnosis, but ongoing challenges and scientific advancements necessitate continued refinement. Based on the dedicated meta-analysis, sensitivity/specificity for MS of Select 3 was 0.88 and 0.77, of Select 6 was 0.82 and 0.89, and of ≥1 PRL was 0.56 and 0.99. In the CAVS-MS pilot, diagnostic performance of Select 6 was similar to CSF-specific OCB (sensitivity 0.71 vs 0.75, specificity 0.86 vs 0.76, p-values >0.05), while Select 3 had similar sensitivity (0.83 vs 0.75, p=0.16), but was less specific (0.48 vs 0.76, p=0.01). The integration of Select 1 and ≥1 PRL demonstrated sensitivity/specificity of 0.76 and 0.93, while the integration of Select 6 and ≥1 PRL demonstrated sensitivity/specificity of 0.57 and 1.00. The updated diagnostic algorithm included CVS as Select 6, and PRL in combination with CSF-specific OCB or dissemination in time.Conclusions: Pooled data showed Select 3 as sensitive, while Select 6 and PRL as specific for MS. Select 6 performed similarly to CSF-specific OCB in a sample similar to clinical referral. Abbreviated CVS counting methods integrated with PRL offer high specificity and may lead to reliable biomarker-based diagnosis of MS.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Clinical Translational Science
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Toljan, Karlo
Advisor dc:contributor.advisor
  • Ontaneda, Daniel
Chair dc:contributor.committeechair
  • Kim-Mozeleski, Jin

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • restricted--full text unavailable until 2027-08-15
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Toljan, Karlo. Susceptibility-based Magnetic Resonance Imaging Biomarkers for the Diagnosis of Multiple Sclerosis. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2025. http://rave.ohiolink.edu/etdc/view?acc_num=case1748881898263655