Case Western Reserve University School of Graduate Studies
Investigation of an Antimicrobial Coating for Intracortical Probes to Reduce Neuroinflammation Associated with Implantation
Abstract
dc:descriptionIntracortical microelectrodes (IMEs) are implanted into cortical brain tissue and can record neural signals for Brain Machine Interfaces (BMI) and basic science applications. A contributor to IME failure is the impact of the permeable blood-brain barrier (BBB). The BBB shows increased permeability as a consequence of IME injury and its continued presence in the tissue. As determined by Hoeferlin et al., microbes were detected at the injury site; the route of invasion was proposed to occur via the blood, impacting neuroinflammation and recording performance of IMEs. Therefore, there is a need for a strategy to reduce neuroinflammation via local mitigation of invasive microbes. Antimicrobial titania nanotube arrays (TNAs) were coated onto the surface of probes and implanted into cortical tissue to investigate the impact of an antimicrobial coating on neuroinflammation at the implant site. One characteristic of TNAs is their ability to be loaded with therapeutics, allowing for controlled, sustained release out of TNAs’ hollow pores. In a second study, the TNAs were loaded with a range of therapeutics, investigating TNAs as a platform for mitigating neuroinflammation at the implant site. A combinatory neuroinflammation mitigation effect was achieved, as the inherent antimicrobial TNA coating can be amplified by antibiotics released or used in tandem with anti-inflammatory therapeutics. An effective strategy for combating several contributors to neuroinflammation is investigated here. The specific aims are detailed in Chapter 1, outlining and contextualizing the studies composing this dissertation. Chapter 2 presents an introduction to the research described in Chapters 3 and 4. The first study is presented in Chapter 3, an investigation into the effect of TNA-coated probes on the relative microbial abundance and neuroinflammatory response. TNA-coated probes showed a reduction in relative microbial abundance and significant changes in neuroinflammatory genes expressed at the implantation site compared to uncoated probes. In Chapter 4, TNA-coated probes were loaded with a range of therapeutics. The therapeutics (anti-inflammatories, antibiotics, and antioxidants) had impacts on neuronal health, autophagy, and immune response proteins expressed in regions around the implant site, with the therapeutics improving neuronal health and reducing neuroinflammation compared to non-therapeutic-loaded TNA-coated probes or uncoated probes.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- Case Western Reserve University School of Graduate Studies
- Year dc:date
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Burkhart, Grace
- Advisors dc:contributor.advisor
-
- von Recum, Horst A.
- Capadona, Jeffrey R.
- Chair dc:contributor.committeechair
-
- Senyo, Samuel
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=case1775138491380284