Back to search

Case Western Reserve University School of Graduate Studies

Integration of Actuation, Imaging, and Control of a Magnetically Actuated, Magnetic Resonance Imaging-Guided Robotic Catheter

Abstract

dc:description

<p>Catheter ablation is an established treatment for refractory arrhythmia. Robotic catheters operating under MRI guidance may offer enhanced control, visualization, and safety. Catheter actuation with current-carrying microcoils is fast and responsive. However, it leads to large void artifacts in MR images. The associated large magnetic field distortions exacerbate the challenging problem of MR-based catheter tracking without device modification. Furthermore, reliable real-time operation requires robust subsystem communication. </p><p>This thesis presents a method to reduce actuation-induced artifacts without compromising catheter actuation capability by interleaving catheter actuation and MR image acquisition at a high switching frequency. Reduction in catheter duty cycle is compensated using effective currents. There is not a statistically significant difference between artifacts associated with the catheter actuating under the proposed interleaving and with the catheter at rest. Catheter motions under pure actuation and under interleaving generally match within tracking error. </p><p>This thesis presents a tracking method using the robotic catheter’s actuation mechanism to enhance device-background contrast without modifying the device or MR system. Because background signal is incompletely suppressed, especially in vivo, MR measurements are combined with model-predicted robot motion in a Bayesian framework. Incorporating Bayesian Filtering improves tracking even when MR measurements are reliable. After simulated addition of in vivo noise, Bayesian Filtering drastically improves tracking performance with errors close to noise-free values even with a multi-fold increase in measurement error. Pilot in vivo results show further promise. </p><p>This thesis presents a server/client architecture for system integration that is configurable to changing subsystem requirements and adaptable to imaging system communication interfaces. A front-end enables user interaction with and influence over downstream processing and control. Because MRI and robot system data have contrasting size and update frequency, two servers are developed. The proposed architecture is demonstrated to enable reliable, real-time data flow between most subsystems for the duration of ablation procedures. </p><p>This thesis integrates robotic control and actuation with MRI guidance to present a magnetically actuated, MRI-guided robotic catheter system for cardiac interventions, with simultaneous/interleaved MR visualization and catheter actuation, robot tracking without modifications to the interventional device or MR acquisition system, and integrated robotic and MR systems.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
EECS - Electrical Engineering
Grantor dc:publisher
Case Western Reserve University School of Graduate Studies
Year dc:date
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ali, Ridaa Zahra
Advisor dc:contributor.advisor
  • Cavusoglu, M. Cenk

Subjects

dc:subject × 18

Rights

dc:rights
Statement dc:rights
  • restricted--full text unavailable until 2028-08-14
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Ali, Ridaa Zahra. Integration of Actuation, Imaging, and Control of a Magnetically Actuated, Magnetic Resonance Imaging-Guided Robotic Catheter. doctoral thesis, Case Western Reserve University School of Graduate Studies, 2026. http://rave.ohiolink.edu/etdc/view?acc_num=case1780910937685777