Back to search

Cleveland State University

A LEFT VENTRICULAR MOTION PHANTOM FOR CARDIAC MAGNETIC RESONANCE IMAGING

Abstract

dc:description

<p>The mammalian left ventricle (LV) has two distinct motion patterns: wall thickening and rotation. The purpose of this study was to design and build a low-cost, non-ferromagnetic LV motion phantom, for use with cardiac magnetic resonance imaging (MRI), that is able to produce physiologically realistic LV wall thickening and rotation.</p><p>Cardiac MRI is continuously expanding its range of techniques with new pulse sequences, including new tissue tagging techniques which allow intra-myocardial deformation to be visualized. An essential step in the development of new cardiac MRI techniques is validating their performance in the presence of motion. MRI-compatible dynamic motion phantoms are of substantial benefit in the development of cardiac specific-magnetic resonance imaging techniques. These phantoms enable the investigation of motion effects images by mimicking the three dimensional motion of the heart. To date, no single study has succeeded in duplicating both LV motion patterns, in an MRI-compatible cardiac motion phantom. In addition, a phantom that is 100% MRI-compatible with low cost to build would be desirable to researchers.</p><p>We have built two MRI-compatible phantoms, housed within a common enclosure and each filled with MRI-visible dielectric gel (as a surrogate to myocardium),which model the wall thickening and rotation motions of the left ventricle independently. The wall motion phantom is pneumatic, driven by a custom non-ferromagnetic pump which cyclically fills and empties a latex balloon within the phantom. The rotation phantom is manually driven by a plastic actuator which rotates the phantom through a specified angular rotation. Each phantom also generates a TTL pulse for triggering the MRI scanner. Although this circuitry contains ferromagnetic materials, it can be located outside the scanner bore.</p><p>The wall thickening motion phantom has been tested using segmented cine, real time cine and grid tagged MRI acquisition sequences. Results were significant with 4% average variability and physiologically realistic wall motion.</p><p>In a separate experiment, the rotation phantom has been imaged using a triggered grid-tagged sequence during a series of repeated 15, 20 and 35 degree rotations. As above, results matched the expected rotation only with 5% average variability.</p><p>In conclusion, we have designed and built a low-cost left ventricular motion phantom, capable of accurately modeling both wall and rotation motions of the left ventricle, with up to 96% repeatability and accuracy for use in evaluating new MRI pulse sequences.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Fenn College of Engineering
Grantor dc:publisher
Cleveland State University
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ersoy, Mehmet
Advisor dc:contributor.advisor
  • Setser, Randolph

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Ersoy, Mehmet. A LEFT VENTRICULAR MOTION PHANTOM FOR CARDIAC MAGNETIC RESONANCE IMAGING. masters thesis, Cleveland State University, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=csu1306471866