Back to search

Cleveland State University

Electrocardiogram Signal Quality Comparison Between A Dry Electrode and A Standard Wet Electrode over a Period of Extended Wear

Abstract

dc:description

<p>The use of a dry electrode (DE), which does not rely on electrolytic solution, may circumvent potential disadvantages of a wet electrode (WE). The accuracy of the electrocardiogram (ECG) signal, provided by the electrode, is vital. The purpose of the study was to investigate if differences in signal quality, reflected by the signal-to-noise ratio (SNR), existed between the standard gel 3MTM Red DotTM 2560 electrode (WE) and the Orbital Research Incorporated (ORI) dry electrode (DE) over a 96 hour period of continuous wear. Assessments were made within electrode types, comparing potential signal deterioration within the electrode over time, and also between the two electrode types, comparing SNR over time. </p><p> Twenty healthy adult volunteers completed the research protocol, each simultaneously wearing the two pairs of electrodes for 96 hours continuously in a lead II configuration. ECG tracings were collected simultaneously on different telemetry channels once a day over five consecutive days. The collection period consisted of six, three minute stages. The six stages included two bouts of rest, supine and standing, followed by three submaximal exercise stages, ending with one stage of standing rest. Data collected using the telemetry unit was de-noised by MatlabTM using sixth order Daubechies wavelet transform technology. </p><p> No significant differences existed within the DE SNRs over time, indicating that SNR deterioration did not occur. Although a significant difference existed within the WE SNR between day 0 and 1 (17.83 ± 2.62 vs. 18.68 ± 2.35 on day 0 and day 1, respectively, p < .01) in the standing stage, the noise was reduced; therefore, SNR deterioration did not occur. The only significant difference (p < .01) between the WE and DE SNRs occurred on day 2 (19.94 ± 2.11 vs. 18.73 ± 1.97) and day 4 (20.16 ± 2.16 vs. 18.96 ± 2.21) in the supine stage, favoring the WE. The difference observed could be attributed to a potential loss of skin contact when in the supine position. No differences were noted at any other stage.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Education
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
College of Education and Human Services
Grantor dc:publisher
Cleveland State University
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schofield, Jamie Rae
Chair dc:contributor.committeechair
  • Sparks, Ken

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Schofield, Jamie Rae. Electrocardiogram Signal Quality Comparison Between A Dry Electrode and A Standard Wet Electrode over a Period of Extended Wear. masters thesis, Cleveland State University, 2012. http://rave.ohiolink.edu/etdc/view?acc_num=csu1334707695