Cleveland State University
A Robotic Neuro-Musculoskeletal Simulator for Spine Research
Abstract
dc:descriptionAn influential conceptual framework advanced by Panjabi represents the living spine as a complex neuromusculoskeletal system whose biomechanical functioning is rather finely dependent upon the interactions among and between three principal subsystems: the passive musculoskeletal subsystem (osteoligamentous spine plus passive mechanical contributions of the muscles), the active musculoskeletal subsystem (muscles and tendons), and the neural and feedback subsystem (neural control centers and feedback elements such as mechanoreceptors located in the soft tissues) [1]. The interplay between subsystems readily encourages “thought experiments” of how pathologic changes in one subsystem might influence another—for example, prompting one to speculate how painful arthritic changes in the facet joints might affect the neuromuscular control of spinal movement. To answer clinical questions regarding the interplay between these subsystems the proper experimental tools and techniques are required. Traditional spine biomechanical experiments are able to provide comprehensive characterization of the structural properties of the osteoligamentous spine. However, these technologies do not incorporate a simulated neural feedback from neural elements, such as mechanoreceptors and nociceptors, into the control loop. Doing so enables the study of how this feedback—including pain-related— alters spinal loading and motion patterns. The first such development of this technology was successfully completed in this study and constitutes a Neuro-Musculoskeletal Simulator. A Neuro-Musculoskeletal Simulator has the potential to reduce the gap between bench and bedside by creating a new paradigm in estimating the outcome of spine pathologies or surgeries. The traditional paradigm is unable to estimate pain and is also unable to determine how the treatment, combined with the natural pain avoidance of the patient, would transfer the load to other structures and potentially increase the risk for other problems.The novel Neuro-Musculoskeletal Simulator described in this work has demonstrated, through simulation and cadaveric experimentation, that it is able to incorporate data from external sensors (e.g. force, motion tracking) to modulate spine biomechanical responses. In addition, the Neuro-Musculoskeletal Simulator exhibited the ability to use an estimated nociceptive response in unilateral facet arthritis to elucidate statistically significant compensatory kinetic and kinematic changes. These changes included a 37% increase in spine shear force, and an 18% increase in applied spine torque.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Engineering
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Fenn College of Engineering
- Grantor dc:publisher
- Cleveland State University
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Colbrunn, Robb William
- Contributors dc:contributor
-
- McLain, Robert
Subjects
dc:subject × 18Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=csu1367977446