Back to search

Cleveland State University

METHOD FOR DETERMINATION OF KINEMATIC SENSOR POSITION AND ORIENTATION FROM MAGNETIC RESONANCE IMAGES

Abstract

dc:description

Concussion and mild traumatic brain injury risk remain high for young athletes participating in helmeted and non-helmeted sports. Because of the short and potential long-term effects on young athletes and early onset Alzheimer's and Parkinson's disease, there is a dire need to correlate a relationship between head impact intensity, frequency, duration and athlete brain health. To address this need, the Cleveland Clinic is developing a custom mouthguard embedded with flexible circuitry and sensors, known as the "Intelligent Mouthguard"(IMG). To accurately quantify peak values of head impacts or concussions, orientation and position of each sensor relative to CG (Center of Gravity) of human head should be calculated.In this study, registration of IMG PCB sensor position and orientation from magnetic resonance images (MRI) was developed and implemented as an image processing method. This method consisted of creating both "Rigid MRI PCB" and "Human MRI PCB" from the same MRI visible material (Fullcure705) having exactly the same dimensions as the IMG PCB. As a Validation Part 1, the "Rigid MRI PCB" was scanned by itself and compared with a reference CAD drawing of the PCB called "CAD Image". In Validation Part 2, "Human MRI PCB" was scanned while inside a volunteer's mouth. Custom written MATLAB code was used as an image post-processing tool in order to extract IMG PCB sensor position and orientation data with respect to the CG of the volunteer's head.In summary, the method expresses a very simple but reliable and efficient way to obtain any position and orientation data with respect to a human subject's head anthropometry. The method gave 0.46 mm maximum difference in position determination and 2.1 degree difference as an angle for orientation. This means if an athlete received an impact which effects CG as 132.7g impact in X direction, impact can be calculated 132.1g or 133.6g from Sensor 3 due to IMG position and orientation inaccuracies. Therefore, IMG measurement uncertainty is in the ±1% range based on sensor position and orientation calculation. Future work should involve in vivo validation testing using more human scans and correlating external anthropometric landmarks with sensors' positions determined by MRI.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Fenn College of Engineering
Grantor dc:publisher
Cleveland State University
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ozturk, Caglar
Contributors dc:contributor
  • Bartsch, Adam

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Ozturk, Caglar. METHOD FOR DETERMINATION OF KINEMATIC SENSOR POSITION AND ORIENTATION FROM MAGNETIC RESONANCE IMAGES. masters thesis, Cleveland State University, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=csu1377015511