Cleveland State University
OPTIMIZATION OF GRADIENT CHROMATOFOCUSING FOR THE PROTEIN SEPARATIONANDLC-MS/MS DETERMINATION OF NGP1-01 IN MOUSE SERUM, BRAIN, AND RETINA
Abstract
dc:descriptionGradient chromatofocusing (GCF) is a chromatographic technique developed by our laboratory that generates linear pH gradients using weak anion-exchange HPLC with inexpensive low-molecular buffer components. This method shows significant advantages over conventional chromatofocusing and salt gradient ion-exchange chromatography in protein separation on DEAE column. In GCF an elution buffer (consisting of multiple acidic buffers with evenly spaced pKa values) is mixed in successively greater proportions with application buffer (composed of multiple basic buffers with evenly spaced pkas), to generate a smooth linear pH gradient. GCF has the advantage of giving an estimate of the protein pI and being able to be directly interfaced to a mass spectrometer when volatile buffers are used. Although GCF yields considerable success in protein separation, extensive study has not been done yet. Further characterization and method optimization studies in GCF are done in the present work. Chapter 1 describes the characteristics of the conventional ion-exchange chromatography, chromatofocusing, and gradient chromatofocusing for protein separation. In the second chapter, a new method with smooth linear pH- gradients on self packed DEAE anion-exchange column was developed by introducing “bridging” buffers between application and elution buffers. This was employed for the chromatographic separation of a mixture of conalbumin, rat albumin, and ß-lactoglobulin which resulted with good resolutions. In the third chapter, the effect of the number of buffer components on protein separation in high-performance gradient chromatofocusing ion-exchange using linear pH-gradients was studied. The results showed that the number of buffer components has significant effect on protein separation. Results showed the increased resolutions and decreased peak widths at half height were obtained with increased number of buffer components. This optimized GCF technique was applied to the separation of prolactin isoforms by a PEI weak anion exchange column.In chapter four, the development and validation according to FDA guidelines of a sensitive quantitative LC-MS/MS method for the determination of a neuroprotective compound, NGP1-01, in mouse serum is described. The developed method was applied to preliminary pharmacokinetic studies to quantify NGP1-01 in limited number of dosed mouse serum samples to show the suitability for undertaking full NGP1-01 pharmacokinetic studies.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy in Clinical-Bioanalytical Chemistry
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- College of Sciences and Health Professions
- Grantor dc:publisher
- Cleveland State University
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Jogiraju, Harini
- Contributors dc:contributor
-
- Anderson, David J.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=csu1389704171