Abstract
dc:descriptionDesign of the fluid flow and heat transfer components utilizing the Computational Fluid Dynamics (CFD) is relatively new yet cheaper and accurate method that becomes popular and reliable today. In this thesis, design of a heat exchanger using CFD analysis technique is considered. A key investigation of this devise is the selection of the tubes and connection them to inlet and outlet manifolds. Correctly selected tube size and tube cross section impacts the heat exchanger performance.Thermal and hydrodynamic performance of the flow in circular and elliptic tubes connected to the inlet and outlet manifolds have been computationally investigated for maximum Figure of Merit. The tube with high Figure of Merit is the one with high heat transfer rate and low pressure drop. The tube has four different configurations of the cross section: a circular tube and three elliptic tubes with aspect ratios = 0.75, 0.50, and 0.25. All tubes are constrained to have the same wetted perimeter and the length, thus have the same heat transfer area. The tube is a smooth straight tube that has the length of 0.3048 m (12 in.) and wetted perimeter of 0.0798 m (3.1416 in.). The tube wall thickness is negligible. The contribution of the inlet and outlet manifolds is examined. A wide range of Reynolds numbers is covered, Re =100 (laminar flow), 10,000 (transitional flow), and 20,000 (turbulent flow). ANSYS FLUENT commercial code has been utilized in this investigation. The code was validated matching with experimental correlations (for developing hydrodynamic and thermal flow) available in the literature. The CFD simulation results were in agreement with the experimental correlation within 5%.This investigation started with simulating 12 different flow conditions inside the tubes without manifolds: three sets with four different tube options (as stated above) in each set. Each set represents the different flow regime: laminar transitional and turbulent with set Reynold number value, as noted earlier. All CFD simulation results were evaluated for their Figure of Merit (“Goodness” factor). The elliptic tube with aspect ratio = 0.25 showed the highest figure of merit for all cases of Re. In the following stage of this research the results of selected tube (aspect ratio = 0.25) was integrated with inlet and outlet manifolds. In this scenario only laminar and turbulent flow regimes were examined. The contribution of the inlet and outlet manifolds overall resulted a negative effect. The reasons of that impact are the following: (1) the inlet flow condition into the tube is no longer uniform (as was assumed in the earlier study), (2) the pressure drop in the manifolds are significantly higher than that in the tube. and (3) the tube length investigated is short. Despite significantly improved thermal characteristics of the tube flow after adding the manifolds, the magnitude of increased friction factor influenced the value of Figure of Merit.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Mechanical Engineering
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Washkewicz College of Engineering
- Grantor dc:publisher
- Cleveland State University
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Aliev, Ruslan
- Contributors dc:contributor
-
- Ibrahim, Mounir
Subjects
dc:subject × 12Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=csu1452678890