Back to search

Cleveland State University

Measurement of Red Blood Cell Oxygenation State by Magnetophoresis

Abstract

dc:description

Magnetophoresis of red blood cells (RBCs) at varying partial pressures of oxygen (pO2) is hypothesized to rejuvenate stored blood to be utilized beyond the FDA regulated 42-day storage time. Magnetophoresis is a particle or cells motion induced by an applied magnetic field in a viscous media. The average magnetophoretic mobility of an oxygenated RBC is -0.126x10-6 mm3-s/kg, and a deoxygenated RBC is 3.66x10-6 mm3-s/kg, presenting magnetophoresis as a resource for RBC rejuvenation in hopes of storing it longer than 42 days. The main objective of this paper was to determine if controlling the pO2 within an RBC suspension, can singly- doubly- triply- or fully deoxygenated RBCs be identified by means of cell tracking velocimetry (CTV). These results agreed with the cooperative binding scheme developed by Hill, especially from ~30-40 to 160 mmHg. From 0 to 30 mmHg, further research must be completed to characterize the binding behavior of oxygen and hemoglobin. The validation of the magnetic energy density gradient value (Sm, currently at 365 T-A/mm2) utilized within CTV, and the exact location for the field of view (FOV, currently set to 4.5 mm from the edge of the magnet assembly) were needed to state particle motion was independent of location within the CTV channel. The FOV location was successfully verified 4.5 mm from the edge of the magnet assembly, however, the Sm value, 880 T-A/mm2, was 140% higher than the original. Spectrophotometry was utilized to validate the oxygenation state of RBCs. Results confirmed spectrophotometry was a reliable model for RBC magnetophoresis. CTV post-processing was tested with glioma progenitor cells. Scatter plots generated for these experiments demonstrated cells with different magnetic mobilities in a sample can be detected. To fully characterize the glioma progenitor cells, more experiments must be completed. Lastly, applying a temperature gradient to the magnetic deposition microscopy (MDM) assembly to enhance the separation of RBCs was explored. Preliminary results determined, introducing a temperature gradient of 40°C was large enough to affect the RBC sedimentation rate in the channel. After, modeling within COMSOL was completed, however, more time and knowledge of COMSOL is needed to generate practical results.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Chemical Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Washkewicz College of Engineering
Grantor dc:publisher
Cleveland State University
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smith, Nina A.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Smith, Nina A.. Measurement of Red Blood Cell Oxygenation State by Magnetophoresis. masters thesis, Cleveland State University, 2019. http://rave.ohiolink.edu/etdc/view?acc_num=csu1568890258014352