Gas Dispersion Using an Up-Pumping Maxflo W Impeller

Abstract

dc:description

Despite known advantages of up-pumping wide-blade axial-flow impellers for gas dispersion, little is known about the design guidelines of these impellers. In the present study, the gas dispersion capabilities of the up-pumping axial-flow Maxflo W impeller in low-viscosity liquids have been characterized to incorporate effects of scale and system geometry. Further, a comparison is made with the dispersion performance of an up-pumping pitch-blade turbine and a radial-flow CD-6. This comparison showed that the up-pumping Maxflo W impeller have dispersion speed, torque and power requirements relatively independent of the gas flow rate, providing the ability to handle varying process conditions.Testing at three scales (tank diameters of 0.29 m, 0.44 m and 0.60 m) indicates that the dispersion capabilities of the up-pumping Maxflo W can be described in terms of a scale-independent aeration number - Froude number relationship. Although a minimum impeller rotational speed is required to disperse low gas flows, the increase in dispersion speed is small with increasing gas flow rate. The effects of geometric parameters such as impeller to tank diameter ratio, sparger size and ungassed liquid height on flooded to dispersed conditions have been investigated. Unlike radial-flow gas dispersion impellers that are not strongly affected by some geometric parameters, the up-pumping Maxflo W dispersion performance is strongly dependent on system geometric parameters. Additionally, small impeller to tank diameter ratios of Maxflo W impellers have been found to perform poorly in gas dispersion operations because of their highly axial discharge flow.It was found that the up-pumping pitched-blade turbine exhibits time-dependent dispersion behavior that can permanently fail to disperse gas after appearing to be capable of dispersion for a reasonably long period of time. For this reason, collection of design data required extended and meticulous testing.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.S.)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemical Engineering
Grantor dc:publisher
University of Dayton
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shaik, Muneeb Ur Rahman
Advisor dc:contributor.advisor
  • Myers, Kevin
Chair dc:contributor.committeechair
  • Janz, Eric

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Shaik, Muneeb Ur Rahman. Gas Dispersion Using an Up-Pumping Maxflo W Impeller. masters thesis, University of Dayton, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=dayton1398961959