Back to search

Kent State University

The Impact of Patient Room Design on Airborne Hospital-Acquired Infections (HAI)

Abstract

dc:description

Transmission of airborne diseases in healthcare facilities is an increasingly important concern. This, in part, is due to the reduction in funding from insurance companies for hospital-acquired infections (HAI) and the consequent economic impact of an influenza outbreak in a hospital. With recent cases of HAI in the USA, it became necessary to examine the current ventilation standards for healthcare facilities. Among the organizations that set standards for the prevention of disease transmission are Facilities Guidelines Institution and the American Society of Heating Refrigeration and Air-Conditioning Engineers (ASHRAE). These standards have played an important role containing airborne transmitted diseases such as Influenza A in North American hospitals. While, design guidelines have focused on recommending appropriate ventilation rates, it ignored the delivery of conditioned air to occupied spaces and the impact of room layout relative to the placement of air supply and return. Airflow is often designed to contribute positively to air-mixing and distribution, improvement of thermal comfort and air quality conditions. Unfortunately, air distribution contributes to airborne pathogen transmission as well. Few studies focused on the relative location of air supply and as well as the impact of the movement of people, but none found focused on the patient room design and layout relative to recommended airflow patterns. This research focuses on a development of a guideline to help designers understand the effect of room design on the distribution of airborne diseases and the Influenza virus in particular. The paper will present the outcomes of several Computational Fluid Dynamic (CFD) simulations of typical room configurations and layouts under many room use scenarios. The model used for simulation is calibrated and verified by field measurements of air distribution patterns in patient rooms. In addition to airflow patterns, the CFD algorithm is used to determine the age of the air to measure the effectiveness of the recommended air changes in the standards. The paper will delineate through graphical and numerical means the potential location for concentrated contaminations and scenarios in which such concentrations may happen. The paper will also estimate the probability of infection based on air change effectiveness, and the relative spatial relationship between HVAC air delivery system and room design. The resulting outcome is suggestions intended to support health facility designers. It is also intended to encourage the development of design codes and standards that take into account airborne pathogen transmission in the room at which the patient is most vulnerable to infection from visitors or staff.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
College of Architecture and Environmental Design
Grantor dc:publisher
Kent State University
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Copeland, Alexa
Advisor dc:contributor.advisor
  • Sharag-Eldin, Adil

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Copeland, Alexa. The Impact of Patient Room Design on Airborne Hospital-Acquired Infections (HAI). masters thesis, Kent State University, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=kent1462362700