Back to search

University of Toledo Health Science Campus

A Comparative Image Quality Analysis between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Radiation Treatment Planning Purposes

Abstract

dc:description

The ability of an imaging system to accurately identify patient anatomy and provide reliable tumor information is critical in the radiation treatment planning process. As image guided radiation therapy and adaptive radiation therapy become more prevalent in treatment procedures, the image quality of these systems could perhaps be a limiting factor in their effectiveness. This research is intended to explore the differences in image quality between two separate imaging modalities commonly used in radiation therapy. A Philips Gemini TF Big Bore PET/CT and Varian True Beam On-Board kV cone beam CT imager were both assessed using the Catphan 504 image quality phantom. Ten different tests were evaluated with the phantom using several routine imaging protocols from both systems. Overall, the image quality between the cone beam and CT system was fairly consistent with one another with the exception of the low contrast detectability measurements. The effects of scatter radiation and image noise significantly reduced the cone beams ability to detect low contrast objects which ultimately degraded its image quality compared to CT.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Sciences (MSBS)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
College of Medicine
Grantor dc:publisher
University of Toledo Health Science Campus
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fentner, David A.
Contributors dc:contributor
  • Dennis, Michael

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Fentner, David A.. A Comparative Image Quality Analysis between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Radiation Treatment Planning Purposes. masters thesis, University of Toledo Health Science Campus, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=mco1372413982