Ohio University
Enhancement of Sensitivity in Capillary Electrophoresis: Forensic and Pharmaceutical Applications
Abstract
dc:description<p>One of the most important issues facing the technology of capillary electrophoresis (CE) is sensitivity. In general, when compared with high performance liquid chromatography (HPLC), CE is a less sensitive technique. This arises from the small dimensions of the CE capillary, which restrict both the volume of sample that can be injected and the optical path length when spectrophotometric detection is used. In this research project, several approaches to improve the sensitivity of CE for the analysis of illicit drugs were investigated and will be discussed. In developing this methodology, we had three main objectives: (1) the development of universal detection techniques for drugs of abuse using systems based on ultraviolet absorption (UV) or native fluorescence and sample stacking; (2) the development of rapid high-sensitivity screening methods for specific classes of drugs using fluorescent derivatization; and (3) the design of more advanced microfluidic systems that permit the coupling of functions such as extraction and/or fluorescent derivatization into a single device. Initial techniques were developed for the analysis of seized drugs and then followed by the analysis of more complex samples, such as blood, urine, or saliva.</p> <p>The application of electrokinetic injection with field amplified sample stacking for opiate drugs analysis is reported herein. Separation was achieved using an uncoated (50 μm I.D.) fused-silica capillary, 77 cm long, containing the detector window 10 cm from the outlet end. The running buffer (pH 6) contained 50 mM sodium phosphate and 0.015 M β−cyclodextrins (β−CDs). Biological samples spiked with the opiate drugs were first extracted and pre-concentrated using an off-line mixed-mode solid-phase extraction procedure and then analyzed by CE. The UV absorbances of these samples were monitored at 214 nm. The effect of the concentration of β−CDs and pH on separation efficiency was also evaluated. The application of electrokinetic injection with field amplified sample stacking resulted in low detection limits, 40-50 ng/mL, and the method had good reproducibility, precision, accuracy, and high recovery.</p> <p>The native fluorescence properties of major opiate drugs were also examined. Normorphine, morphine, 6-acetyl morphine (6-AM), and codeine were analyzed by CE-native fluorescence without any derivatization and detected at an excitation wavelength of 245 nm with a cutoff emission filter of 320 nm. This technique provided a rapid and simple analysis. Separation conditions, analytical characterization, method optimization, and validation were reported. The detection limits were in the range of 200 ng/mL, which was higher than the UV absorbance method. However, the native fluorescence detection proved to have better specificity than UV detection, especially for the analysis of biological samples.</p> <p>For a highly sensitive analysis, laser-induced fluorescence (LIF) detection was performed using a two-step pre-column derivatization procedure. In this method, drugs extracted from human urine were first subjected to a <em>N</em> -demethylation reaction involving the use of 1-chloroethyl chloroformate (ACE-Cl), derivatized using fluorescein isothiocyanate isomer I (FITC), and analyzed by CE coupled to a LIF detector. Variables affecting this derivatization include the yield of the demethylation reaction, the concentration of FITC, and the reaction time and temperature. The estimated detection limits of the FITC-derivatives were in the range of 50-100 pg/mL, using LIF detection with excitation and emission wavelengths of 488 nm and 520 nm, respectively. The linearity, reproducibility, and reliability of the methods were also evaluated. In addition, a comparison of the characteristics for both native fluorescence and LIF detections will be discussed.</p> <p>Finally, a number of chromatography-based pre-concentration techniques were investigated. These techniques offer two significant advantages: (1) the ability to pre-concentrate the analytes, and (2) the ability to eliminate most of the interfering matrix. Several methods were developed and validated for the determination of illicit or abused drugs in biological fluids using various extraction techniques, including solid-phase extraction, membrane pre-concentration, and solid-phase microextraction. A comparison of the analytical characteristics of each method will be discussed. The proposed CE methods allow on-line extraction, pre-concentration, and separation of abused drugs in a single run.</p>
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (PhD)
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Chemistry (Arts and Sciences)
- Grantor dc:publisher
- Ohio University
- Year dc:date
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Al Najjar, Ahmed Omer
- Advisor dc:contributor.advisor
-
- McCord, Bruce
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1107276943