Back to search

Ohio University

<em>In Vitro</em> Simulation Experiments for the Implementation of a Nocturnal Hypoglycemic Alarm Based on Near-Infrared Spectroscopy

Abstract

dc:description

<p>Non-invasive glucose monitoring has been the subject of considerable research in recent years because of the high number of diabetic patients who must monitor their glucose levels daily by taking blood samples. Among methods being evaluated for possible use in this application, near-infrared spectroscopy has received significant attention because of the availability of glucose absorption bands that can be observed in the presence of the large aqueous background found in tissue spectra. The research described in this thesis has employed transmission measurements in the combination region of 4000 to 5000 cm <sup>-1</sup> .</p> <p>To help understand the instrumental and data handling requirements for a successful non-invasive glucose determination in this spectral region, <em>in vitro</em> simulations are implemented that represent the obstacles of making a non-invasive glucose measurement through the pinna of the ear. Simulation experiments were designed to implement the glucose excursions that occur in diabetics during sleep. An electrochemical glucose analyzer is employed to establish the glucose concentration that matches each collected spectrum. The data acquired through these simulation studies are subsequently used to develop protocols for implementing a nocturnal hypoglycemic alarm. The alarm simulation is based on the collection of consecutive spectra over the sleep period. A reference glucose measurement is made at the start of the experiment and the subsequently collected spectra are used to determine if the glucose level falls below an alarm threshold of 3.0 mM.</p> <p>Initial experiments were performed with a simple matrix of glucose and water. A layered cell was constructed so that layers representing other components of the ear pinna could be added. In this work, cartilage isolated from a pig ear was placed behind the glucose solution. Due to the highly scattering nature of the cartilage, instrumental modifications were required in order to increase the intensity of transmitted light so that glucose information could be determined. The <em>in vitro</em> experiments described in this research represent an initial step toward the implementation of a nocturnal hypoglycemic alarm.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemistry (Arts and Sciences)
Grantor dc:publisher
Ohio University
Year dc:date
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Medford, Cynthia
Advisor dc:contributor.advisor
  • Small, Gary

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Medford, Cynthia. <em>In Vitro</em> Simulation Experiments for the Implementation of a Nocturnal Hypoglycemic Alarm Based on Near-Infrared Spectroscopy. masters thesis, Ohio University, 2004. http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1108144876