Programmed harmonic reduction in inverters and controlled rectifiers

Abstract

dc:description

<p>Optimal force-commutated current-source ac/dc, voltage-source dc/ac, and chopper-type ac/ac converters with minimum input-current or output-voltage harmonics are proposed. The minimization of rectifier input-current harmonics or inverter output- voltage harmonics is achieved through numerical solution of optimal firing and extinction angles for the switches. The method is superior to the conventional harmonic elimination techniques, in terms of its harmonic distortion, operating zone, and flexibility.</p> <p>Conventional harmonic-elimination methods are compared with the proposed technique for ac/dc, dc/ac, and ac/ac single-phase converters. The distortion- minimization technique eliminates certain chosen harmonics while minimizing harmonic distortion in rectifier input current or inverter output voltage. Choosing fewer harmonics to be eliminated results in lower harmonic distortion; the lowest possible distortion results from allowing all harmonics to have non-zero values. A striking characteristic of the optimal solutions for the ac/dc, and ac/ac chopper converter is the absence of quarter- wave symmetry, resulting in either leading or lagging power factors of the converters.</p> <p>Other applications of the proposed method are: the ac/dc control of static VAR compensators, and active filters with minimum harmonic distortion. The SVC compensates reactive power demand and minimizes the harmonic distortion of the other phase-controlled converters as well as its own distortion. The active filter injects harmonics into the ac bus out of phase with existing ones, resulting in harmonic cancellation. The optimized injection has an advantage over the conventional harmonic elimination technique in terms of the lower total distortion and converter rating.</p> <p>In addition the optimization method can be applied to the cascaded, phase-controlled HVDC converters. An optimal firing strategy for N cascaded, 6- or 12-pulse converters of a HVDC link is proposed, in either unipolar or bipolar operation. Simultaneous control of the firing angles of the N converters (for both the inverters and rectifiers) can be utilized for either harmonics minimization, or reactive power demand reduction. With relatively low values of N (4 12-pulse, or 8 6-pulse), the resultant ac-current harmonics, or reactive power demand are substantially lower than for comparable 12- or 6-pulse converters. Also, the dc-voltage harmonics are greatly reduced over phase-control operation.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical Engineering & Computer Science (Engineering and Technology)
Grantor dc:publisher
Ohio University
Year dc:date
1993

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Deib, Deib Ali
Advisor dc:contributor.advisor
  • Hill, Jr., H.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Deib, Deib Ali. Programmed harmonic reduction in inverters and controlled rectifiers. doctoral thesis, Ohio University, 1993. http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1173759592