Ohio University
Comparison of a Novel Cell-based Reporter Assay and a Competitive Binding ELISA for the Detection of Thyrotropin-Receptor (TSHR) Autoantibodies (TRAb) in Graves’ Disease Patients
Abstract
dc:description<p>The pathogenesis factor of Graves’ Disease (GD) has been widely accepted as autoantibodies against thyrotropin receptor (TSHR) over-stimulating follicular cells to produce excess thyroid hormones. For the last few decades, the competitive binding assay for TSHR antibody (TRAb) has been the most commonly used assay for the differential diagnosis of GD. The competitive binding assay measures the heterogeneous mixture of TRAbs in the patients’ sera that prevent labeled thyroid stimulating hormone (TSH) or monoclonal stimulating TRAb from binding to the fixed human recombinant or porcine TSHRs.</p> <p>In this study, a new cell based reporter assay with chimeric human TSHR (Mc4) was evaluated against the third generation competitive binding Enzyme-Linked Immuno Sorbent Assay (ELISA). Mc4 utilizes its mechanism to detect only the simulating TRAbs in the patent sera that directly correlate with GD hyperthyroidism. Furthermore, a Mc4 predicate, a cell based reporter assay with human wild type (hWT) TSHR (CHO-Luc), was evaluated. This study conducted comparisons of these three assays on the same group of GD patients (n = 200) and healthy blood donors (HBD) (n = 40).</p><p>Overall sensitivities given the sample provider’s diagnosis as the reference standard were similar with all three assays (84.0 – 73.4%). Mc4 had the second highest sensitivity (79.5%) without misdiagnosing normal controls (specificity = 100%). Sensitivity comparison was ambiguous since some of the 200 GD specimens had high TSH and might have been receiving antithyroid drug treatments which interfered with the assay results. When GD positive groups were divided with TSH levels, agreements of all the assay results were the highest within the very low TSH (TSH < 0.01 µIU/mL) group. Interpretation of TRAb ELISA gave different performance measures (sensitivity and specificity) within the same sample set.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Engineering (Engineering and Technology)
- Grantor dc:publisher
- Ohio University
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hata, Misako
- Chair dc:contributor.committeechair
-
- Goetz, Douglas
Subjects
dc:subject × 21Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1262099140