A Parametric Study of Stack Performance for a 4.8kW PEM Fuel Cell

Abstract

dc:description

Parametric testing was conducted to determine the effects of reactant stream temperature, pressure, humidity and flow rate on the voltage and power output of a 4.8kW PEM fuel cell (FC) stack. The effect of physical orientation and coolant temperature on the voltage and power output of the FC stack is discussed. It was determined that the reactant flow rates could be reduced to approximately 90% of the manufacturer's recommended values without significantly affecting the performance of the FC stack. Increasing reactant stream temperature, pressure, and relative humidity increased the power output of the FC stack. The power output of the FC stack was shown to be sensitive to reactant stream temperatures. This effect was more pronounced for loads below approximately 100A. The power output of the FC stack was also observed to increase with increasing coolant temperature. This effect was greater for higher loads. Reactant stream pressure was observed to cause a nearly uniform shift in the ohmic region of the FC stack's polarization curve. The difference in the power output between the high and low pressures tested was approximately 8% from 0-200A load. The power output of the FC stack was not sensitive to changes in the reactant stream relative humidity for values above 70%. Reactant stream relative humidity was shown to have a more pronounced effect for loads less than 100A. The FC stack's physical orientation did not affect the stack's power output for inclinations less than 13.5°. The time required for the FC stack to reach a steady state voltage following abrupt load changes was not significantly different for different step sizes. The voltage observed within 0.1 seconds of all load changes was always within 2% of the steady state value. Based on the results of this study, the FC stack that was tested is well suited for its intended automotive application.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering (Engineering and Technology)
Grantor dc:publisher
Ohio University
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Edwards, Tyler A.
Advisor dc:contributor.advisor
  • Kremer, Greg

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Edwards, Tyler A.. A Parametric Study of Stack Performance for a 4.8kW PEM Fuel Cell. masters thesis, Ohio University, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1275667559