Ohio University
Post Construction Stormwater Best Management Practices: Exfiltration Trench: Performance and Design Assessment
Abstract
dc:descriptionThe exfiltration trench (ExT) is one of the BMPs that the Ohio department of Transportation (ODOT) is using to remove pollutants from stormwater runoff. A 1-year study was conducted on an ExT located in Reno, OH. Samples from the stormwater runoff and trench's effluent were collected. These samples were tested for water quality parameters (COD, turbidity, oil and grease). The results showed that the ExT was able to reduce COD in the runoff by 24.5%, turbidity by 33.9%, while oil and grease removal was indeterminable. Maintenance was necessary to remove accumulated sediments which caused clogging of the porous concrete surface. However, pollutants removal after maintenance did not improve considerably. Using total suspended solids and COD data, the first flush (FF) volume was estimated. The required length of the ExT to capture the FF was estimated by numerical solution. The solution showed that the required length was much larger than the length estimated using ODOT's equations.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Civil Engineering (Engineering and Technology)
- Grantor dc:publisher
- Ohio University
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Souri, Ahmad F.
- Advisor dc:contributor.advisor
-
- Mitchell, Gayle
- Chair dc:contributor.committeechair
-
- Sargand, Shad
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1336576509