Previous studies on hot biopsy forceps for colorectal polypectomy indicated that simulated ablation tests could provide useful information on hot biopsy forceps design and ablation parameter optimization that would help reducing the rate of potential polypectomy complications such as perforation. In this thesis, a novel ex vivo ablation test model for colonoscopic monopolar hot biopsy forceps was designed and implemented; simulated ablation tests had also been performed on this ablation test model for (a) verifying the model design and implementation, and (b) finding the roles of the major ablation parameters in tissue injury during the ablation process. In the design of this novel ex vivo ablation test model, a body equivalent block was introduced to simulate the properties of the human body. Porcine colon was used as tissue source for the simulated ablation tests. Major ablation parameters that were tested on this model covered (a) output power level, (b) firing duration, (c) contact area at the electrode tip, and (d) electrical impedance. Simulated ablation tests that were performed on this ablation test model covered the main combinations of targeted ablation parameters. During simulated ablation tests various ablation sites were generated under different parameter combinations, which indicated that this ablation test model can be used for hot biopsy forceps ablation studies. Some ablation parameters such as output power level and firing duration had dominating effects on the resulting ablation site geometry and tissue injury. The simulated test results showed the potential applications for testing hot biopsy forceps and optimizing ablation parameters.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering (Engineering and Technology)
Grantor dc:publisher
Ohio University
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chen, Liang
Advisor dc:contributor.advisor
  • Choi, JungHun

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Chen, Liang. Novel Ex Vivo Ablation Test Model for Monopolar Hot Biopsy Forceps. masters thesis, Ohio University, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1389353998