New techniques for characterization of surface and volumetric wear in total hip athroplasty
Abstract
dc:descriptionTotal hip arthroplasty is a common method of alleviating the pain of osteoarthritis of the hip joint and allowing return to function. Since the introduction of synthetic hip joint replacements in 1962, wear of the implant has been a major concern. One of the major causes of implant failure is aseptic loosening believed to be caused by excessive amounts of wear debris generated during the repeated articulation of a femoral head component across an acetabular cup. New methods for analyzing this wear are constantly being introduced. Optical profilometry (OP) is one such method allowing for close examination of relatively small areas. OP not only generates a qualitative image of the surface but can also be used to calculate various quantitative measures of roughness. We have performed various statistical analyses to correlate these values with various characteristics of an implant including duration and perceived mode of failure. Correlations found between quantitative, qualitative, and implant retrieval data are revealed. While high magnification surface analysis is common, the effects of large scale damage on implant longevity are often overlooked. An area containing large scale damage will likely exceed debris generation associated with microscopic damage. This damage can occur in various stages during surgical implantation. The use of a bone skid, common in canine medicine but rare in human medicine, is explored and a correlation between the amount of surface area exhibiting intraoperative instrument abrasions and in vivo duration was found. With this emphasis on specific areas exhibiting more macroscopic wear, a new way to determine volumetric wear was created. The resolution of the current methods fall far short of what is needed for new implant materials. We utilized a new system involving three-dimensional laser micrometry. The current accuracy of the system is approximately 1 µm; the potential for accuracies in the submicron range clearly exists. With the development of extensive software allowing control, acquisition and display of large amounts of data (e.g., 145,000 data points), this allows for complete surface analysis of both new hard bearings and old polymer-based implants to provide estimates of volumetric loss and tunneling. Total hip arthroplasty is a common method of alleviating the pain of osteoarthritis of the hip joint and allowing return to function. Since the introduction of synthetic hip joint replacements in 1962, wear of the implant has been a major concern. One of the major causes of implant failure is aseptic loosening believed to be caused by excessive amounts of wear debris generated during the repeated articulation of a femoral head component across an acetabular cup. New methods for analyzing this wear are constantly being introduced. Optical profilometry (OP) is one such method allowing for close examination of relatively small areas. OP not only generates a qualitative image of the surface but can also be used to calculate various quantitative measures of roughness. We have performed various statistical analyses to correlate these values with various characteristics of an implant including duration and perceived mode of failure. Correlations found between quantitative, qualitative, and implant retrieval data are revealed. While high magnification surface analysis is common, the effects of large scale damage on implant longevity are often overlooked. An area containing large scale damage will likely exceed debris generation associated with microscopic damage. This damage can occur in various stages during surgical implantation. The use of a bone skid, common in canine medicine but rare in human medicine, is explored and a correlation between the amount of surface area exhibiting intraoperative instrument abrasions and in vivo duration was found. With this emphasis on specific areas exhibiting more macroscopic wear, a new way to determine volumetric wear was created. The resolution of the current methods fall far short of what is needed for new implant materials. We utilized a new system involving three-dimensional laser micrometry. The current accuracy of the system is approximately 1 µm; the potential for accuracies in the submicron range clearly exists. With the development of extensive software allowing control, acquisition and display of large amounts of data (e.g., 145,000 data points), this allows for complete surface analysis of both new hard bearings and old polymer-based implants to provide estimates of volumetric loss and tunneling.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kohm, Andrew Christopher
- Contributors dc:contributor
-
- Lannutti, John
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1070378403