Control of power converters for distributed generation applications

Abstract

dc:description

The contributions of this Ph.D. research include the application of a modified space vector pulse width modulation (MSVPWM) scheme combined with robust servomechanism control in a three-phase four-wire split dc bus inverter and real-time implementation of Newton-Raphson Method on digital signal processors for on-line power system identification and power flow control of a distributed generation (DG) unit. This dissertation addresses digital control strategies of solid-state electric power converters for distributed generation applications in both island and grid-connected modes. Three major issues of DG, island operation, grid-connected operation, and front-end converter control, are discussed with proposed solutions and related analysis. In island mode, a control approach is developed for a three-phase four-wire transformerless inverter system to achieve voltage regulation with low steady state error and low total harmonic distortion (THD) and fast transient response under various load disturbances. The control algorithm combines robust servomechanism and discrete-time sliding mode control techniques. An MSVPWM scheme is proposed to implement the control under Clarke's reference frame. The robust stability of the closed-loop system is analyzed. In grid-connected mode, a real and reactive power control solution is proposed based on the proposed voltage control strategy for island operation. The power control solution takes advantage of a system parameter identification method and a nonlinear feedforward algorithm, both of which are based on Newton-Raphson iteration method. The proposed technique also performs grid-line current conditioning and yields harmonic free grid-line current. A phase locked loop (PLL) based algorithm is developed as a part of the solution to handle possible harmonic distorted grid-line voltage. In a DG unit with three-phase three-wire ac-dc-ac double conversion topology including a controlled power factor correction (PFC) front-end rectifier, unbalanced inverter load could cause current and voltage fluctuation on the dc bus. Mathematical analysis is conducted to disclose the mechanism of the dc bus voltage ripple and a notch filter based rectifier control strategy is proposed to eliminate the impact of the ripple and yield balanced input current. The effectiveness of the techniques proposed in this dissertation is demonstrated by both simulation and experimental results.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dai, Min
Contributors dc:contributor
  • Keyhani, Ali

Subjects

dc:subject × 11

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Dai, Min. Control of power converters for distributed generation applications. doctoral thesis, The Ohio State University, 2005. http://rave.ohiolink.edu/etdc/view?acc_num=osu1124329850