The effects of rigid contact lens center thickness, material transmissibility, and blinking on oxygen shortfall of the human cornea
Abstract
dc:description<p>Corneal oxygenation during the wear of rigid contact lenses occurs both by passage of oxygen through the lens material itself and by introduction of oxygen containing tears beneath the lens during blinking. This study sought to assess the oxygen transmitting performance of the high Dk rigid contact lens materials Fluoroperm 92, Fluoroperm 151, Menicon SF-P, and Menicon Z under both static (blinking) and dynamic (non-blinking) conditions. Oxygen shortfall units (osu's) were used to evaluate performance of these materials at center thicknesses of 0.12 mm, 0.16 mm, and 0.20 mm while other lens parameters were held constant. Corneal oxygen uptake rates were measured on ten adult human subjects using a polarographic technique.</p> <p>Oxygen shortfall responses after wearing a Fluoroperm 92 lens were significantly greater than oxygen shortfall after wear of any of the other materials (p = 0.000 1). Oxygen uptake rates were also significantly greater when the lens center thickness was 0.20 mm compared to 0.12 mm, although the oxygen shortfall induced was still fairly low. No statistically significant difference was noted between static or dynamic wear of the lens materials.</p> <p>Relative data obtained was also compared to data previously obtained by two examiners utilizing the same technique and lens materials. Using the same subject population and contact lenses as a previous examiner, this study resulted in oxygen shortfall measurements for Menicon SF-P manufactured in 1995 and Menicon Z that were marginally lower than previously found (p = 0.0780). Using a different subject population and lens batch than a previous examiner, oxygen uptake was measured as significantly greater with Fluoroperm 92 than previously documented, while lower reading were obtained for the Menicon SFP manufactured in 1992 (p = 0.0020). No difference was found for Fluoroperm 151.</p> <p>The study outcomes suggest several conclusions. First, this study would suggest that very high Dk rigid lens materials do not produce significantly different oxygen shortfall of the human cornea among materials or significantly high oxygen shortfall even with moderate increases in center thickness. Clinicians should therefore have greater flexibility in lens material selection and lens fitting parameters when Dk is above a given level. Second, this study suggests that with very high Dk rigid contact lenses the tear pump plays only a minor role in corneal oxygenation. Finally, this study suggests that comparison of oxygen shortfall produced by different lens materials should be based upon measurements taken by the same examiner on the same subjects to avoid confounding of data by other variables.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Physiological Optics
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 1999
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Patterson, Hope Ann
- Advisor dc:contributor.advisor
-
- Fink, Barbara
Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1159556692