Development of a Dynamic Model of a Counterflow Compact Heat Exchanger for Simulation of the GT-MHR Recuperator using MATLAB and Simulink

Abstract

dc:description

<p>A computational model was developed to determine the dynamic behavior of counter flow compact heat exchangers. This code was written with the intention of becoming a component of a larger system dynamics model of a Brayton cycle nuclear power plant. Several configurations for the GT-MHR recuperator were analyzed, but the code can easily be modified to analyze many types of compact heat exchangers with a variety of applications. Helium was the working fluid used in this project, but the code can be modified to use other gases. This code was written in Matlab and Simulink but the methods outlined in this report could be easily reapplied in other programming languages. This code is also useful for designing counter flow compact heat exchangers in general.</p><p>In this model the heat exchanger is discretized in time and in space. The resolution of the discretization is defined by the user. Helium properties are reevaluated for each volume before each time step. The dynamic inputs to the model are the inlet temperature, mass flow rate and pressure for each side of the heat exchanger. This model assumes low Mach number flows and treats the propagation of pressure and mass flow rate changes as instantaneous. The outlet temperature and pressure drop for each side is determined. The results of the simulation were successfully validated against results available in the literature. Contact the author for a copy of this code.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Nuclear Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hawn, David Phillip
Chair dc:contributor.committeechair
  • Blue, Thomas

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Hawn, David Phillip. Development of a Dynamic Model of a Counterflow Compact Heat Exchanger for Simulation of the GT-MHR Recuperator using MATLAB and Simulink. masters thesis, The Ohio State University, 2009. http://rave.ohiolink.edu/etdc/view?acc_num=osu1236091152