The Ohio State University
Protein deployment onto a model field effect transistor silicon dioxide sensing surface
Abstract
dc:description<p>Biosensors are analytical devices, which convert biological interactions into electrical signals. Biosensors based on field effect transistor (FET) architecture, or semiconductor biosensors, in general, are representative of the merger between molecular biology and electronics. A novel modification to existing FET biosensors, called the pH-modulation FET sensor is in its developmental stage. In common with previous FET biosensors, biological analytes bind specifically to a FET channel coated with biological affinity reagents (peptides and antibodies) and induce a local charge transfer changing the FET conductance. Our design allows extraction of additional analytical information from the bound analyte. By controlled manipulation of channel pH, multiple charge parameters determined by the analyte's primary amino acid sequence are examined. Observation and measurement of the charge transfer at various pHs is expected to result in a signature that can be compared to a reference profile for a specific analyte. In principal, the strategy should increase sensitivity and decrease error rates.</p><p>There are several steps to realize the proposed sensor. This thesis focuses on one of them, the issue of optimizing conditions for protein deployment on the sensing channel of the device. For this purpose a model system was generated, which used diced silicon dioxide wafers to mimic the gate oxidation step of actual FET channel, and used streptavidin-biotin interactions as the model detection system. The first series of experiments used direct-physical absorption to deploy streptavidin onto diced silicon dioxide chips, using enzyme linked immunosorbent assay (ELISA) and fluorescence microscopy for analysis. The results indicated that little streptavidin bound to the "flat" regions of the silicon dioxide surface, but seem to preferentially bind to its edges and surface asperities.</p><p>The second series of experiments used a focused ion beam to produce well-defined patterns into a silicon dioxide chip surface. This series of experiments still used direct-physical absorption for protein deposition, and atomic force microscopy and fluorescence microscopy for analysis. The results at first seemed to suggest physical texturing of the silicon dioxide surface promoted preferential protein binding, but upon further examination the findings were inclusive, and streptavidin was observed to be weakly bound to the silicon dioxide surface. The results from the first two rounds of experiments suggested that direct-physical absorption would not be a sufficient method of deploying protein for the final device.</p><p>The third and final round of experiments employed a silane to "functionalize" the silicon dioxide surface, and used ELISA for analysis. The results indicated that silanized surfaces, with its covalent bonds, bound streptavidin to the silicon dioxide surface with more consistency, reliability, and stability than direct-physical absorption, thus suggest its use in the final device for protein deployment.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Barnes, Phillip Deshawn
- Advisor dc:contributor.advisor
-
- Lee, Stephen C.
Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1269370207