The Ohio State University
Design and Validation of an Intensity-Based POF Bend Sensor Applications in Measuring Three-Dimensional Trunk Motion
Abstract
dc:description<p>Many efforts have been put forth to better understand proper trunk posture while in motion. Such efforts include wearable devices such as the Lumbar Motion Monitor that track the three dimensional motion of the trunk over time.37 Often these devices are prohibitively expensive, heavy, and cumbersome for subjects attempting to move naturally for sports or biomechanics research. Recent developments in plastic optical fiber (POF) quality have made it possible to build an inexpensive bend sensor for applications in measuring trunk motion on the job.6 An intensity-based POF bend sensor is not only lightweight, noninvasive, and simple to build, but provides a signal with almost no processing requirements. The purpose of this thesis is to fabricate an inexpensive, wearable POF bend sensor suitable for dynamic motion and to test its use for recording the three-dimensional motion of the trunk.</p><p>The fabrication of a POF bend sensor vest is described as well as its validation with a Vicon passive optical motion capture system. Overall, the lateral and sagittal vest data correlated with the Vicon system to within ±3.8° of average curvature or 11.5% or less of the total range of motion for each dimension. While jogging RMS error increased to ±6.7° when compared to the Vicon system, the average range of motion captured from the vest correlated to within ±2.2° of the Vicon range of motion data. Preliminary work was also accomplished for twisting motion with an average percent RMS error of 13.2% for range of motion trials.</p><p>Considering the low-cost and non-invasive nature of the POF bend sensor, these results show promise for using this sensor in a variety of applications. These applications include feedback monitoring of motion for injury prevention or sports performance or for assessment of lifting techniques in the workplace. Future work would involve characterizing the reliability of the sensor over long periods of time as well as capturing all three dimensions of motion simultaneously.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Brush, Ursula Jane
- Advisor dc:contributor.advisor
-
- Chaudhari, Ajit
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1269456459