Back to search

The Ohio State University

Cooling Capacity Assessment of Semi-closed Greenhouses

Abstract

dc:description

Leading Dutch researchers reported significant benefits to closed greenhouse systems. Ooteghem (2007) simulation studies of optimal control in a closed greenhouse environment predicted 52% heating fuel saving and 39% increase of tomato crop yield using a heat recovery system whose major components included heat pumps, heat exchangers and aquifers. Opdam et al. (2005) reported 19% primary energy saving, 22% yield increase, 80% chemical reduction, and 50% irrigation water saving for tomato production in a closed greenhouse. Although the Dutch researchers successfully demonstrate year-round operation of closed greenhouses, their success benefited from the mild weather and availability of aquifers, not always the case for other geographical regions. Results of this study using Ohio conditions estimated that 90% and 92% of CO2 loss through cooling and dehumidification ventilations when an elevated CO2 level of 800 ppm must be maintained. This study also found that for Wooster, Ohio to achieve economical year-round closure, due to the larger weather variation and lack of accessibility to aquifers, a better economical return would be expected with semi-closed designs that allow the greenhouse to vent when the heat load is approaching a certain percent of peak levels. For example, a 50% peak load design can meet the cooling and dehumidification needs of a closed greenhouse for 92% and 90% of the year, respectively. Also determined in this study was the amount of heat which can be recovered with thermal storage. Potential recoverable heat of a closed greenhouse at Wooster, Ohio can contribute up to 23%, 25% and 98% of total heating needs of the year, 2006, with 1-day, 2-day and year-round thermal storage capacities, respectively. The models used for the above analyses were evaluated using data collected in a greenhouse located at Wooster, OH. Convection and infiltration heat loss prediction were validated during cloudy and clear sky nights. The results gave prediction disagreements of 0.2% to 2% and 30% under cloudy and clear sky conditions, respectively. Also evaluated was the potential recoverable heat from ventilation exhaust. Result showed that ventilation time prediction disagreement were -8.2% and 0.8%, when net solar radiation transmittances were estimated at 0.54 and 0.57, respectively. Although further improvements of this model could be done, the data processing framework established for the heat recovery strategy evaluation is valuable for the assessment of potential benefits of semi-closed greenhouse.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Food Agricultural and Biological Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lee, Wee Fong
Advisor dc:contributor.advisor
  • Ling, Peter P.

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Lee, Wee Fong. Cooling Capacity Assessment of Semi-closed Greenhouses. masters thesis, The Ohio State University, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=osu1274996517