Investigation of low consumption system to reach part per trillion detection limits for μL sample volume

Abstract

dc:description

There are many fields in which the available sample volume is the limiting factor for an elemental analysis. Over the last ten years, sample introduction systems used in plasma spectrometry (i.e., Inductively Coupled Plasma Atomic Emission Spectrometry, ICP-AES, and Mass Spectrometry, ICP-MS) have evolved in order to expand the field of applicability of these techniques to the analysis of micro- and nanosamples. In order to maintain the detection limits of ICP-MS at part per trillion level with micro and nanosamples delivered at μL/min sample uptake rate it is necessary to have a higher percent of analyte entering the plasma than at mL/min sample uptake rate. Below 20 μL/min sample uptake rate the droplet number density decreases causing a drop in droplet-droplet collisions and coagulation and a possible total evaporation of all liquid aerosol. At these low sample uptake rate droplet-droplet collisions is not the major factor limiting analyte transport efficiency. Using a Mira Mist CE nebulizer and a 4 mL single pass spray chamber, a solution delivered at sub µL sample uptake rate was combined with a make-up delivered at µL sample uptake rate. The same transport efficiency (66.7±2.5% and 64.9±3.0 % in average) was found from these two solutions. Therefore, even though the sample is diluted by a make up flow, the ICP-MS signal for the analyte in the sub-μL sample flow should not be degraded by use of a 1 to 5 μL/min make up flow. In order to improve the transport efficiency of the analyte in aqueous solution, the walls of the spray chamber were heated. A conventional 4 mL spray chamber and a 4 mL spray chamber designed with an extra outlet near the injector where a sheath argon gas was were heated with 90°C water and up to 309°C respectively. With the first introduction system and a Mira Mist CE an analyte transport efficiency of 82.2%±2.6 % was measured between 2 and 14 µL/min. With the second spray chamber and a Meinhard High efficiency nebulizer an analyte transport efficiency of 83.9%±2.1 % was measured between 2 and 100 µL/min. The high volatility, low density and higher vapor pressure of organic solvent compared to water allows more sample entering the plasma which cause the ICP-MS to be linearly proportional to the sample flow rate from 1 to 14 µL/min . Since about 80% of the sample is introduced in the plasma and the sample uptake rate is low, the matrix effect should be drastically reduced. By using aqueous standard to calibrate, concentrations of solutions of known concentrations are within a factor of 1.7, 2.0, 2.6 and 3.4 from their true value for solution in methanol, dichloromethane, dioxane and xylene respectively. However for some analysis determining the concentration of solution by a factor of 2 may be sufficient. And there is no need to dispose of organic standard.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemistry
Grantor dc:publisher
The Ohio State University
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Linard, Elodie
Advisor dc:contributor.advisor
  • Olesik, Susan

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
related terms
citation

Linard, Elodie. Investigation of low consumption system to reach part per trillion detection limits for μL sample volume. masters thesis, The Ohio State University, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=osu1275460359