Back to search

The Ohio State University

Contributions of Silicone Hydrogel Transmissibility and Tear Exchange to Corneal Oxygen Supply

Abstract

dc:description

Purpose: The purpose of this study is to evaluate the physiological performance of 4 silicone hydrogel contact lens and 2 rigid lens materials. The difference in corneal oxygen uptake measured under static and dynamic wearing conditions, which provides an indication of the amount of tear exchange that takes place with the blink, will be compared. Methods: Corneal oxygen uptake was measured on the right eye of 15 subjects after 5 minutes of static (no blinking) and dynamic (blinking every 5 seconds) wear of the following lens materials: Senofilcon A (Vistakon Acuvue Oasys, 14.0 mm diameter), Comfilcon A (Cooper Biofinity, 14.2 mm diameter), Silfilcon A (Ciba O2 Optics, 13.2, 14.0, and 14.8 mm diameters), Lotrafilcon (Ciba Night & Day, 13.8 mm diameter), Menicon Z (8.8 mm diameter), and polymethylmethacrylate (PMMA) (8.8 mm diameter). Measurements were relativized to those recorded with no lens and with the PMMA lens. Friedman’s test was used to compare the mean relativized data across the contact lens materials. Post-hoc comparisons were performed using the methods described by Conover to control the alpha level for multiple comparisons. Results: There were significant differences (p=0.019) in the difference values between static and dynamic condition data across lens materials/designs. The difference values, from highest to lowest, were associated with Ciba Night & Day, O2 Optics/14.0 diameter, O2 Optix/14.8 diameter, O2 Optix/13.2 diameter, Cooper Biofinity, Menicon Z, Acuvue Oasys. Conclusions: Corneal oxygen demand differences among contact lens materials and designs are related to both corneal oxygen dynamics (lens transmissibility) and tear exchange (influenced by lens design and modulus).

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Vision Science
Grantor dc:publisher
The Ohio State University
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Harp, Lisa
Advisor dc:contributor.advisor
  • Fink, Barbara

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Harp, Lisa. Contributions of Silicone Hydrogel Transmissibility and Tear Exchange to Corneal Oxygen Supply. masters thesis, The Ohio State University, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=osu1275496222