Abstract

dc:description

<p>Abdominal Aortic Aneurysms (AAAs) are localized bulges in the lower aortic artery tissue. AAAs are prone to rupture, an extremely dangerous event, in which the aorta rips open and blood is allowed to flow freely into the body’s internal cavity. The fatality rate for ruptured AAAs is over 50% so preventative surgery is the preferred method of treatment. However many AAAs never rupture and the risks involved with preventative surgery are not negligible. Clinicians therefore must decide when the risks of AAA rupture outweigh those of preventative surgery.</p><p>The current clinical metric for determining the risk of AAA rupture is the transverse diameter. A 5.5 cm diameter is the suggested max allowable size. As many as 20-30% of AAAs below this threshold rupture and in practice, the operating surgeon must account for other risk factors too such as blood pressure and aneurysm shape. As a result, the decision is no more than an educated guess based on a series of known risk factors. There is a clinical desire for a more reliable and comprehensive AAA rupture risk metric.</p><p>Studies have shown that maximum arterial wall Von-Mises stress, calculated using patient-specific finite element (FE) models outperforms diameter with regards to predicting AAA rupture. Modern AAA FE models employ fully coupled dynamic fluid-structure interaction (FSI) techniques in an effort to accurately measure max wall stress in-vivo and non-invasively.</p><p>Published boundary conditions (BCs) for dynamic AAA model fluid domains typically involve standard flow rate and pressure conditions being applied at the inlet and outlet of the model respectively. Our lab proposes using in-vivo blood velocity measurements from phase-encoded velocimetry MRI scans to generate patient-specific fluid BCs. A patient-specific flow rate condition is applied at the inlet matching the velocimetry data read in at the inlet. A patient-specific downstream pressure is applied at the outlet. This pressure BC is derived from an optimization routine which seeks to match the modeled and measured outlet flow rates by altering the impedance at the outlet.</p><p>To date, only one model has been run to convergence, due to a computation run time of over 1 month. While changes were made to the pressure condition at the outlet (a 14% increase in dynamic range) during optimization, these changes had almost no effect of the max arterial wall stress.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • McElroy, Mark Allen
Advisor dc:contributor.advisor
  • Ghadiali, Samir

Subjects

dc:subject × 11

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

McElroy, Mark Allen. A Procedure for Generating Finite Element Models (FEM) of Abdominal Aortic Aneurysms with Fluid Boundary Conditions Derived from Magnetic Resonance Imaging (MRI) Velocimetry. masters thesis, The Ohio State University, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=osu1284670607