Back to search

The Ohio State University

Quantification of Fourth Generation Kapton Heat Flux Gauge Calibration Performance

Abstract

dc:description

<p>Double sided Kapton heat flux gauges which are used routinely by the Ohio State University Gas Turbine Laboratory are driven by two main calibrations, the sensors temperature as a function of resistance and the material properties of Kapton. The material properties separate into those that govern the steady-state response of the gauge and those that influence the transient response. The steady-state response, as it forms the key to data processing, will be the topic of this investigation and is based on the thermal conductivity divided by the thickness (k/d). </p><p>Calibration accuracies for the heat flux gauge sensors reached levels on the order of +-.05 °C and were well within the target accuracy of +- 0.1 °C over a 100 °C calibration range. Time degradation of the gauges did occur and for these cases and a single point calibration method is introduced that maintains the accuracy to ±0.4 °C instead of the ± 3 °C that would have resulted from the resistance shift due to erosion. This method will allow for longer use of the gauges in the turbines. </p><p>Various calibration methods for k/d were investigated and performed. Of the three methods presented, a hot air method provided the best results of a single value. For 1 mil Kapton k/d was calculated to be between 8520 - 8882, or a k = 0.2164 - 0.2256 W/mK (a 4% variation). Different gauge thicknesses were calibrated using a variety of methods resulting in similar values of thermal conductivity, although each method had different limitations on its accuracy.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hodak, Matthew Paul
Advisor dc:contributor.advisor
  • Haldeman, Charles

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Hodak, Matthew Paul. Quantification of Fourth Generation Kapton Heat Flux Gauge Calibration Performance. masters thesis, The Ohio State University, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=osu1285038898