Ultrasonic Control of Ultrafiltration Membrane Fouling by Surface Water: Effects of Calcium, pH, Ionic Strength and Natural Organic Matter (NOM) Fractions

Abstract

dc:description

Ultrasound at a frequency of 20 kHz and a power of 16 W was applied to a cross-flow ultrafiltration system to investigate the ultrasonic control of surface-water fouled ceramic membranes. Also, the impact of solution chemistry on fouling in the absence and presence of ultrasound was studied. Ultrasound was effective in improving the normalized permeate flux from 0.21 in the absence of ultrasound to 0.70 with the aid of ultrasound. Moreover, a stable permeate flux was obtained throughout the 2 hour filtration process, which is important for maintaining satisfactory production. Parameters of solution chemistry we investigated had little impact on membrane fouling in the absence of ultrasound (in terms of both fouling rate and fouling extent); however, Ca and pH played more important roles in ultrasonic fouling control: lower calcium concentration and moderate pH values were more amenable to ultrasonic control. This difference in fouling behavior between ultrasound and no ultrasound conditions was attributed to the different factors controlling membrane fouling in the presence and absence of ultrasound. Further investigation of NOM fractions suggests that the hydrophilic fraction dominated fouling behavior in the absence of ultrasound, and the ultrasonic control was mainly affected by foulant-foulant and foulant-membrane interactions, which were presumably controlled by the adsorption or binding effects in the hydrophobic fraction. NOM fractionation experiments revealed that fouling in the absence of ultrasound by the hydrophilic fraction was less dependent on calcium concentration and pH. On the other hand, for ultrasonic control, lower calcium concentration, and moderate pH increased the cleaning efficiency probably due to weaker foulant-foulant and foulant-membrane adhesion caused by less humic adsorption and binding effects.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Environmental Science
Grantor dc:publisher
The Ohio State University
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gao, Yuan
Advisors dc:contributor.advisor
  • Weavers, Linda
  • Walker, Harold

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Gao, Yuan. Ultrasonic Control of Ultrafiltration Membrane Fouling by Surface Water: Effects of Calcium, pH, Ionic Strength and Natural Organic Matter (NOM) Fractions. masters thesis, The Ohio State University, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=osu1285123886