dc:description<p>The goal of the present study is to predict the stable operating limit of centrifugal compression systems and the transition from mild to deep surge, including discrete sound peaks at low frequencies and their amplitudes at key locations throughout the system. Two different compression system configurations were studied. One configuration incorporated a plenum (large volume), which produced surge as the flow rate was reduced. The other configuration consisted of the smallest possible downstream volume, allowing compressor performance measurements left of the surge line of large volume. A set of small and large volume configurations installed on the turbocharger facility at The Ohio State University (OSU) were studied along with additional experimental results available in the literature (Fink, 1988). A compressor map preprocessor was developed in the present study to extrapolate and interpolate the data from the small volume systems. To facilitate surge predictions, each map was incorporated into a one-dimensional (1-D) model of the corresponding large volume configuration, including an upstream compressor duct, a centrifugal compressor, a downstream compressor duct, a plenum, and a throttle.</p><p>The model of Fink’s large volume compression system was used to simulate a mild surge operating point, with the frequency, amplitudes, and time-averaged values of nondimensional flow rate, pressure ratio, and rotational speed nearly reproducing the corresponding experimental observations from the literature. The frequency of measured and predicted mild surge oscillations occurred at the theoretical Helmholtz resonator frequency. As the flow rate was reduced, the compression system entered deep surge and the frequency decreased below the Helmholtz resonator value. The predictions captured the dominant cycle period and the four distinct phases (quiet, instability growth, blowdown, and recovery) reported in the literature. The model also correctly predicted a decrease in the cycle period and the elimination of the quiet phase as the flow rate was further reduced. During the instability growth phase, the amplitude of the secondary Helmholtz resonator oscillations was smaller in predictions relative to the measurements.</p><p>The turbocharger facility at OSU incorporated a variable volume plenum to change the surge frequency. The predicted stable operating limit occurred just left of the peak pressure ratio and was nearly constant for the plenum volumes studied, which agreed closely with the measurements. As the flow rate was reduced, the compression system entered mild surge, with the frequency of simulated and experimental oscillations occurring near the theoretical Helmholtz resonator frequency. With a further reduction in flow rate, the compression system entered deep surge. The dominant deep surge frequencies at full (9.2 L) plenum volume occurred at 63 and 50% of the mild surge frequency for the experiment and simulation, respectively. As the plenum volume was decreased to one-eighth (1.15 L), the dominant deep surge frequencies increased to 82 and 88% of the mild surge frequency for the experiment and simulation, respectively. In agreement with the experimental trends, the predicted deep surge line moved to lower mass flow rates as the plenum volume was decreased, however, the predicted flow rates were larger relative to the measurements. During mild and deep surge, a frequency domain analysis reveals that the dominant predicted sound pressure levels agree reasonably well with the measurements.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dehner, Richard D.
- Advisor dc:contributor.advisor
-
- Selamet, Ahmet
Subjects
dc:subject × 12Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1306934392