Back to search

The Ohio State University

Labeled and Label-less Magnetic Cell Separation and Analysis using Cell Tracking Velocimetry

Abstract

dc:description

<p>Magnetic cell separation and related analysis technology continues its maturation with practioners demanding higher system performance using cells with either magnetically labeled or based on the intrinsic magnetic properties of cells. Typical performance metrics include a very high purity and recovery of the targeted cells or a high level of removal of undesired cells while still recovering the majority of desired cells. While this technology is widely used in biological or clinical research laboratories for diagnostic or therapeutic applications, there still exist many engineering challenges. These challenges include unique system designs or cells with various magnetic susceptibilities, and a more fundamental understanding of the magnetic cell separation process.</p><p>In this dissertation, an instrument referred to as cell tracking velocimetry was used and further perfected as a powerful analytical tool to assist in this continued improvement of magnetic cell separation technology and approaches. For the first time, side by side comparison of two versions of the CTV magnets: permanent verses electromagnet version, on the same targets were compared. The accuracy and sensitivity of the two versions of CTV system was evaluated, and suggestions were made for choice of version for experimental targets with different magnetic susceptibilities. Also, single particle magnetization measurement of micron sized magnetic particles was made possible by the CTV. Three types of commercially available magnetic particles were studied as examples in this study. The average magnetization values from cell tracking velocimetry were found to have good agreements with the reported values from commercially used instruments which usually output only a bulk value. </p><p>With respect to magnetic cell separation systems, immuno-labeled magnetic cell separation was carried out for the application of T cell depletion for the purpose of a mismatched, bone marrow transplantation. Flow simulations using FLUENT were carried out to explore flow rate and shear stress effect on separation results. A number of parameters in the particle labeling and magnetic separation part were optimized for two new types of immuno magnetic particles used in the study. Also, separation results analyzed by CTV were compared to results obtained from flow cytometry; advantages and limitations for this method were also discussed. Additionally, this study theoretically and experimentally explored the relationship between magnetic pressure and shear stress in terms of separation system performance. Shear stress, often neglected in the process of magnetic cell separation, plays an important role in breaking antibody antigen bond, non-specific binding of particles and cells, and direct affecting separation results.</p><p>Magnetic cell separation utilize the intrinsic magnetic properties of cells were carried out in the practice of red blood cell separation and algae separation for biofuel production. For red blood cell, with the need of continuous separation of weakly paramagnetic red blood cells with relatively high separation efficiency, the new continuous magnetic separation system was designed to replace the previously tested catch and release batch mode system. Continuous in-line deoxygenation was also made possible with a hollow fiber liquid gas contactor, and new design of deoxygenator was pursued to solve the cell loss problem. The separation efficiency of the continuous system was tested and confirmed to be comparable to the high gradient batch mode system. Large scale red blood cell separation was made possible with continuously running a multiple, 2 by 2 systems. For algae, a preliminary study on the intrinsic magnetophoresis of some algae stains was carried out, and improvement on their magnetic susceptibilities used either genetic modifying stains or media optimization techniques. CTV results and further separation test confirmed the feasibility of magnetic separation of algae cultures from large volume of solutions.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemical and Biomolecular Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Xu, Jie
Advisor dc:contributor.advisor
  • Chalmers, Jeffrey

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Xu, Jie. Labeled and Label-less Magnetic Cell Separation and Analysis using Cell Tracking Velocimetry. doctoral thesis, The Ohio State University, 2012. http://rave.ohiolink.edu/etdc/view?acc_num=osu1335296870