Back to search

The Ohio State University

Peri-implant Indices of Remodeling as a Response to Mechanical Loading

Abstract

dc:description

<p>Background: The current study aims to detect peri-implant tissue changes that may occur due to bone and soft tissue remodeling as a response to mechanical loading.</p> <p>Material and methods: Systemically healthy, non-smoking adults with a single posterior edentulous space with intact proximal natural teeth were recruited. Inclusion criteria were: adult patient, systemic health, periodontal health, single tooth posterior edentulous space, non-smoking, no grafting needed, and ability to consent to treatment. Exclusion criteria included presence of parafunctional habits and implants placed with significant angle precluding screw retained implant crowns. Peri-implant tissue changes were recorded prior to crown delivery and 1, 3, 6 and 12 weeks in function. Clinical parameters were: plaque and gingival indices (PI and GI), Resonance Frequency Analysis (RFA), and crevicular fluid (CF) samples of the implant and adjacent teeth. CF volume was determined using a calibrated electronic volume quantification unit. Samples were stored at -80°C. Multiplex assay was performed for cytokine detection. Polymerase Chain Reaction was used to detect the presence of eight putative microflora. Data was analyzed using multiple model regression analysis corrected with Bonferroni adjustment. Correlation analysis was conducted by calculating Spearman correlation coefficient, statistical significance was accepted at p<0.05.</p> <p>Results: Sixteen patients were recruited and fifteen completed the study. Mean healing time prior to loading was 6.1±0.3 months. Implant Stability Quotient (ISQ) increased from 76.5±1.7 to 83.7±1.7 units (P<0.001). Peri-implant plaque accumulation was statistically lower than adjacent periodontal plaque accumulation at baseline (P=0.02) and this difference between groups stayed significant throughout the observation weeks (P<0.004). Peri-implant gingival index was statistically lower compared to adjacent periodontal gingival index before loading and at 1 week following loading (P<0.05). No difference between implant and adjacent tooth sites for GI at follow-up appointments (P<0.05). Peri-implant GI increased observed by 12 week was statistically significant compared to baseline (P=0). Gingival crevicular fluid (GCF) was statistically higher than peri-implant crevicular fluid (PICF) prior to loading (P=0.03). PICF increased following loading and was significantly greater than GCF at 1, 3, 6 and 12 weeks (P<0.04). Post-loading peri-implant crevicular fluid was statistically higher than pre-loading crevicular fluid when compared to baseline value (P=0.004). No significant differences in periodontal and peri-implant probing depths or the keratinized tissue width throughout the study (P>0.05). </p> <p> Cytokines: PDGF, IL-4, IL-6, IL-7, IL-10, IL-12, IL-17, Eotaxin, FGFb, IFN¿¿¿¿¿¿ and TNFα were expressed at detectable but low levels at both PICF and GCF samples with no significant differences throughout the observation period. IL-1¿¿¿¿¿¿, IL-8, G-CSF, IP-10 and VEGF presented higher expression levels in gingival crevicular fluid samples compared to PICF samples prior to loading with no statistically significant difference. Following one week of loading, there was approximately a two fold increase in peri-implant crevicular fluid IL-1¿¿¿¿¿¿, IL-8 and MIP-1b levels although the differences were not statistically significant. VEGF and MCP-1 levels showed a trend towards increased expression at one week (P<0.05). Other cytokines, G-CSF and IP-10, were expressed at higher levels at both PICF and GCF samples following 3 weeks of loading compared to before loading values. The differences were not statistically significant (P<0.05). Microbiology data showed the presence of certain putative periodontal pathogens throughout observation period in a transient fashion. </p> <p>Conclusion: Within the limits of this study, it appears that mechanical loading following a traditional osseointegration period has significant effect on implant stability and peri-implant clinical indices used to evaluate soft tissue healing and health. However, the expression of pro-inflammatory cytokines and the presence of certain putative periodontal pathogens show significant variations among individuals.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Dentistry
Grantor dc:publisher
The Ohio State University
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gurney, Michael Lynn
Advisor dc:contributor.advisor
  • Leblebicioglu, Binnaz

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Gurney, Michael Lynn. Peri-implant Indices of Remodeling as a Response to Mechanical Loading. masters thesis, The Ohio State University, 2012. http://rave.ohiolink.edu/etdc/view?acc_num=osu1337800531