Abstract
dc:descriptionGated cardiac imaging (GCI) is used in oncology and cardiology to improve resolution impaired by cardiac motion. Both subjects require specific imaging techniques to accurately portray the inner functionality of the human heart. Positron emission tomography (PET) is a sensitive imaging technique that details the cardiac cycle by recording the three dimensional distribution of radiotracer photon emissions. Unlike the commonly used computed tomography (CT) method which transmits source particles through the target, the PET source emits positrons from within the object, capitalizing on opposing photon emissions for anomaly detection. Within PET imaging, gated cardiac PET using an 18F-fluorodeoxyglucose (18F-FDG) source is a quantitative imaging technique which utilizes a gating technique that reduces signal blurring in the cardiac cycle. This paper evaluates 18F-FDG uptake within gated cardiac PET while developing an elementary interactive data language (IDL) program for gated cardiac PET data analysis. Digital Imaging and Communications in Medicine (DICOM) standards were used to understand PET imaging output, and DICOM conformance was used to determine the DICOM tags required for analysis. The IDL program has two objectives: to read DICOM tags integral to gated PET into the program and to develop a user interface which displays gated PET images in correct sequence. Five gated PET datasets were used to compare and verify the output of the IDL program to the output of verified and authorized EBW/LEO DICOM display workstations. Quantified results show an average end-diastolic volume (EDV) of 25.6 ml, average end-systolic volume (ESV) of 13.8 ml, and a left ventricle ejection fraction (EF) of 51.8 percent. Additionally, results show that the IDL program’s 1-dimensional (1D) trans-axial display matches the output from authorized workstations. In particular, the IDL program provides a graphical user interface (GUI) which facilitates visibility of gated images organized by frame and by slice, allowing the user to easily customize the axial view for further analysis. Thus, the IDL program can be utilized as a promising tool to allow multi-pharmaceutical, multi-modality medical imaging technology users to obtain information of interest utilizing an easy-to-use format.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Nuclear Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Lin, Jonathan Lee
- Advisor dc:contributor.advisor
-
- Cao, Lei
Subjects
dc:subject × 13Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1342817999