The Ohio State University
Vertical ground reaction force estimation using position data measured from a markerless motion capture system
Abstract
dc:descriptionGround reaction forces (GRFs) are important quantities in biomechanical analyses, as they may be used to diagnose neuromuscular impairments and provide a quantified measure of asymmetries between a patient’s legs. Using force plates, GRFs can be measured accurately, but force plates limit studies to a laboratory setting where subjects may not move as naturally as they would in other settings. Using position data obtained from motion capture systems, GRFs can be calculated without the need for a force plate. With marker-based (MB) motion capture systems, the most widely used motion capture method, studies are still limited to a dedicated laboratory setting. A newer motion capture technique, markerless motion capture (MMC), uses video cameras and does not need a laboratory setting for testing. MMC allows for motion measurements of the entire body without requiring reflective markers on body segments, tracking body segments, or calculating the mass, center of mass, and moments of inertia for each segment. The whole body center of mass position, velocity, and acceleration can be determined without the need for any of these. This thesis is about using MMC to estimate GRFs. In this research, MMC data of nine female subjects performing running and single-leg landing (SLL) movements was recorded. From the center of mass accelerations obtained from this, vertical GRFs were calculated and compared to force plate data to determine the method’s accuracy. Results showed that during running trials, GRFs were calculated with maximum error of less than 10%, but during SLL trials, errors greater than 50% were observed during impact. Visual hulls in running and SLL trials had additional volume that may have caused errors in center of volume position, which would then result in errors in calculated vertical GRFs. The errors caused by extra volume were analyzed using three different approaches. First, the volume of each subject was calculated using an average density value and compared to the visual hull volume. Second, the volumes of basketball visual hulls were compared to the computed volume for a sphere. Third, the change in volume of a cylinder, used as a model of the human body, caused by an increase in radius and height was calculated. These experiments suggested that visual hulls had greater volume than the calculated value because of additional volume and increased thickness of the outside of the body. Improved results could be obtained with the same method if we have more cameras or cameras with higher resolution. Additionally, accuracy would be improved during studies involving impact if cameras with higher frame rates were used. Given that our method used only the center of volume of the visual hull, there is potential for improving ground reaction force calculations using methods that take advantage of other information in the visual hulls, for instance, by fitting segmental models to the visual hulls.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Scalley, Timothy Brian
- Advisor dc:contributor.advisor
-
- Srinivasan, Manoj
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1345557063