The Ohio State University
Three Dimensional Displacement of Nine Different Abutments for Cement-Retained Crowns Using a Specific Torqueing Protocol on a Tapered Screw-Vent Implant
Abstract
dc:descriptionPurpose: Many aftermarket abutments for cement-retained crowns are available for the Tapered Screw-Vent implant (Zimmer Dental, Carlsbad, CA, USA). Displacements between the implant and abutment occur during routine torquing and re-torquing procedures that may occur causing prosthetic complications. This study was performed in two parts: Part I was to measure and compare the three –dimensional (3-D) displacement between screw tightening by hand and torque driving to 30 Ncm of nine different abutments for cement-retained crowns on an implant with an internal hexagon platform. Part II was to evaluate the 3-D displacement after a second torque was applied 10-minutes after the initial torque to compensate for embedment relaxation.Material and Methods: Nine 4.1mm x 11.5mm Tapered Screw-Vent implants were placed into a 12” x 2” x 8mm resin block. Five abutment specimens of each of the nine different abutments (45 total) were tried into one of the nine implants. Initially, the abutments were torqued to 20 Ncm, representing hand tightening during laboratory fabrication. The abutments were then tightened using a torque wrench to the manufacturer recommended torque of 30 Ncm. After 10 minutes had elapsed, another 30 Ncm torque was applied with a torque wrench. Another 10 minutes elapsed before testing was completed. The spatial relationship of the abutments to the resin block was determined using three-dimensional digital image correlation (3D DIC), an optical measurement technique. Images were recorded in12-second intervals for the entire testing. Commercial image correlation software (VIC 3D, 2009, Correlated Solutions, Inc. Columbia, SC, USA) was used to analyze the displacements 10 minutes after the initial 30 Ncm torque and 10 minutes after the second 30 Ncm torque. Mean displacements for each of the nine different abutments were calculated in all three dimensions and for overall displacement in space for both torque applications. A t-test with a step-down Bonferroni correction was used for a pairwise comparison of each abutment’s mean displacements to the other abutments to determine statistical differences for both torques (a=.05).Results: After the initial 30 Ncm torque was applied, the Atlantis Titanium, the Inclusive Custom Titanium, and the Legacy Zirconia Straight Contoured abutments showed statistically significant higher mean displacements than other abutments in the horizontal direction (P<0.0144). The overall three-dimensional distance traveled by the Atlantis Titanium abutment after the first torque (about 16 µm) was significantly higher than 6 of the 8 other abutments (P< 0.0144). After the second torque was applied, the Atlantis Titanium abutment (about 9 µm) was significantly higher than 2 of the 8 other abutments (P<0.0144). Conclusion: When selecting an abutment for cement-retained crown on a Tapered Screw-Vent implant, the displacement between hand-tightening and torqueing should be taken into consideration. Specifically, when choosing a custom titanium abutment, the Zimmer PSA had less displacement than the Atlantis Titanium and Inclusive Titanium Custom abutments. The Atlantis titanium abutment had significantly more movement than other abutments after each torque application (P<0.0144). Re-torquing after a 10-minute interval results in small displacements for all abutments. In particular, the Atlantis Titanium abutment showed significantly greater displacement from two other abutments tested; however, the movement was in the opposite direction of the first torque displacement causing the abutment to approximate its original position.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Dentistry
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gilbert, Andy Ben
- Advisor dc:contributor.advisor
-
- Yilmaz, Burak
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1377012394