Back to search

The Ohio State University

MRI Artifacting of Monocortical Screw/Polymethylmethacrylate Constructs in Canine Cadaveric Cervical Vertebral Columns

Abstract

dc:description

Postsurgical magnetic resonance imaging (MRI) is seldom performed for fear of poor image quality; however, MRI studies evaluating implant related artifacts in the canine vertebral column are lacking. Six canine cadaveric cervical vertebral columns were instrumented with monocortical titanium (Ti) screws and six with stainless steel (SS) screws. The imaging protocol consisted of the following sequences: T1-weighted, T2-weighted, STIR and SPIR. A scoring system (0-1-2-3) was used to rank evaluator ability to assess a total of 20 different regions of interest across four contiguous vertebrae (C3-C6). Ti monocortical screw/PMMA constructs produced significantly less susceptibility artifacting compared to SS constructs. Postoperative imaging with the intent to evaluate the spinal cord should not be avoided in patients with Ti screw constructs, but may cause mild artifacting associated with the osseous structures at the implanted site. Conversely, SS screw constructs will cause more severe susceptibility artifacts hindering interpretation of the implanted site; however, evaluation of anatomic structures outside the implanted site may be possible. Additionally, variations in implant positioning and angle may cause alterations in the location and degree of susceptibility artifacting.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Comparative and Veterinary Medicine
Grantor dc:publisher
The Ohio State University
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jones, Brian G.
Advisor dc:contributor.advisor
  • Hettlich, Bianca

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Jones, Brian G.. MRI Artifacting of Monocortical Screw/Polymethylmethacrylate Constructs in Canine Cadaveric Cervical Vertebral Columns. masters thesis, The Ohio State University, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=osu1397716311