The Ohio State University
Validation of VO2max Assessment and Magnetic Resonance Cardiac Function Measurements Utilizing an MRI Compatible Treadmill
Abstract
dc:descriptionAbstractMaximum oxygen consumption (VO2max) is considered the gold standard for assessment of cardiorespiratory fitness. Likewise, MRI is considered the gold standard for quantification of cardiac function; however, the MRI-compatible equipment required to combine these two measures has not been available to date. We utilized a specially designed MRI-compatible treadmill, and modified oxygen uptake equipment to eliminate the ferromagnetic components of the mask and headgear to perform a standard VO2max treadmill test immediately adjacent to a clinical MRI system. We sought to determine if values for a VO2max test performed in an MRI room utilizing MRI-compatible equipment were valid and accurate when compared to those obtained in an exercise lab with typical equipment set up. Ten recreationally trained subjects completed two VO2max tests to volitional fatigue in two different settings; an exercise lab and an MRI room. Oxygen and carbon dioxide were measured continuously using a computerized system. Secondary criteria were assessed to confirm maximal exercise. Resting and peak exercise images of the heart were taken before and after maximal exercise to measure global cardiac function parameters including end systolic volume (ESV), end diastolic volume (EDV), cardiac output (CO) and left ventricular ejection fraction (LVEF). VO2max values were different (P=0.033) between testing locations (47.6±8.11 vs 50.0±10.7). All subjects met or exceeded a RER =1.10 and RPE =17 at peak exercise.iii(35.6 s. ± 3.8 s.) elapsed between the end of exercise and start of imaging. At rest vs immediately following peak stress, CO was (5.1 ± 1.0 vs 16.4 ± 5.6) and LVEF was (65.2 ± 3.3 vs 78.4 ± 4.8). Simultaneous VO2max testing was completed in 7 recreationally trained healthy individuals for comparison of the inter-unit variability in two ParvoMedics TrueOne 2400 systems. Despite the equipment modifications required to measure VO2max in the MRI environment, VO2 measurements correspond to those obtained in the exercise lab. The differences in both separate and simultaneous testing produced <4-6% error, within acceptable criteria according to national certification bodies, manufacturers specifications, and previously published studies. MRI-VO2max combined testing offers potential for advanced investigation of exercise physiology and cardiopulmonary disease.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- EDU Physical Activity and Educational Services
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- LaFountain, Richard A.
- Advisors dc:contributor.advisor
-
- Devor, Steven
- Simonetti, Orlando
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1405431417