Back to search

The Ohio State University

Validation of VO2max Assessment and Magnetic Resonance Cardiac Function Measurements Utilizing an MRI Compatible Treadmill

Abstract

dc:description

AbstractMaximum oxygen consumption (VO2max) is considered the gold standard for assessment of cardiorespiratory fitness. Likewise, MRI is considered the gold standard for quantification of cardiac function; however, the MRI-compatible equipment required to combine these two measures has not been available to date. We utilized a specially designed MRI-compatible treadmill, and modified oxygen uptake equipment to eliminate the ferromagnetic components of the mask and headgear to perform a standard VO2max treadmill test immediately adjacent to a clinical MRI system. We sought to determine if values for a VO2max test performed in an MRI room utilizing MRI-compatible equipment were valid and accurate when compared to those obtained in an exercise lab with typical equipment set up. Ten recreationally trained subjects completed two VO2max tests to volitional fatigue in two different settings; an exercise lab and an MRI room. Oxygen and carbon dioxide were measured continuously using a computerized system. Secondary criteria were assessed to confirm maximal exercise. Resting and peak exercise images of the heart were taken before and after maximal exercise to measure global cardiac function parameters including end systolic volume (ESV), end diastolic volume (EDV), cardiac output (CO) and left ventricular ejection fraction (LVEF). VO2max values were different (P=0.033) between testing locations (47.6±8.11 vs 50.0±10.7). All subjects met or exceeded a RER =1.10 and RPE =17 at peak exercise.iii(35.6 s. ± 3.8 s.) elapsed between the end of exercise and start of imaging. At rest vs immediately following peak stress, CO was (5.1 ± 1.0 vs 16.4 ± 5.6) and LVEF was (65.2 ± 3.3 vs 78.4 ± 4.8). Simultaneous VO2max testing was completed in 7 recreationally trained healthy individuals for comparison of the inter-unit variability in two ParvoMedics TrueOne 2400 systems. Despite the equipment modifications required to measure VO2max in the MRI environment, VO2 measurements correspond to those obtained in the exercise lab. The differences in both separate and simultaneous testing produced <4-6% error, within acceptable criteria according to national certification bodies, manufacturers specifications, and previously published studies. MRI-VO2max combined testing offers potential for advanced investigation of exercise physiology and cardiopulmonary disease.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
EDU Physical Activity and Educational Services
Grantor dc:publisher
The Ohio State University
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • LaFountain, Richard A.
Advisors dc:contributor.advisor
  • Devor, Steven
  • Simonetti, Orlando

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

LaFountain, Richard A.. Validation of VO2max Assessment and Magnetic Resonance Cardiac Function Measurements Utilizing an MRI Compatible Treadmill. masters thesis, The Ohio State University, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=osu1405431417