Back to search

The Ohio State University

Subspace Techniques for Parallel Magnetic Resonance Imaging

Abstract

dc:description

Parallel magnetic resonance imaging (pMRI) is an attempt to accelerate data acquisition by simultaneously collecting subsampled k-space data from multiple surface coils. The different sensitivity patterns for the various coils provide aspatial encoding and permit recovery from subsampled or otherwise aliaseddata. The smooth coil sensitivities in the image domain multiply with the single image representing the spin density of the excited slice. Via the Fourier transform, this can be written as a convolution of k-space representations of the coil sensitivities and the image. Since both the sensitivities and image are unknown in reality, this problem can be formulated as a blind multichannel deconvolution problem in the fully sampled case and this formulation allows us to use the established literature in signal processing to remedy the problems in parallel magnetic resonance imaging. In this thesis, we particularly focus on subspace techniques to estimate both the coil sensitivities and the calibration kernels of the parallel imaging methods. Subspace techniques can also be used to extract information about the spin density image.Inversion techniques are widely used in parallel imaging, where the effect of coil sensitivities and aliasing are unfolded from the multichannel observations. These techniques require knowledge of coil sensitivities. As a common method, a low-pass approximation of the true spin density function is obtained first and then coil sensitivities are calculated by removing the effect of the true image from the coil images. This approximation is conventionally either obtained directly from a body-coil or from a coil combined image, for example calculated using square-root sum-of squares (SoS) combination approach. However, acquiring a body coil image increases the data acquisition time and also can be sensitive to motion and B0 field inhomogeneities. On the other hand, SoS combination gives biased and low-contrast images. In this dissertation, subspace concepts are shown to be effective to obtain an estimate of coil sensitivities in k-space. From there, it is possible to extract the calibration kernels of the coil-by-coil reconstruction methods such as GRAPPA, SPIRiT and PRUNO using the explicit formulas given in this dissertation. As a result, this formulation provides a unified framework for the inversion and the coil-by-coil interpolation reconstruction techniques. Coil sensitivities or calibration kernels of parallel imaging algorithms are conventionally extracted from a region of fully sampled low-pass calibration data. However, for high acceleration rates, the acquisition of the fully sampled calibration data becomes a limiting factor.Thus, we also investigate extraction of coil sensitivities and calibration kernels from subsampled reference or ACS lines. We present a non-iterative, subspace-based approach to the recovery of the coil sensitivity functions from a nonuniformperiodically sampled auto-calibration signal (ACS) region ofk-space, providing flexibility to balance high-frequency detailwith low-frequency signal strength. The non-iterative algorithmhas low computational complexity, consistent with clinicallyrelevant reconstruction times. A system theoretic analysis provides a proof of uniqueness of coil sensitivities for a special class of non-uniform periodic sampling.For parallel MRI, interpolation techniques such as GRAPPA are widely employed due to fast computation times and robust image reconstruction. GRAPPA reconstruction, however, suffers from noise amplification, especially at high acceleration rates. We propose a pre-processing approach to suppress noise by exploiting structure in matrices obtained from fully sampled and uniformly subsampled acquired data. In particular, Hankel-block-Hankel and low-rank properties are jointly enforced on linear operators constructed from acquired k-space data. By itself, the proposed pre-processing technique provides 1-6 dB enhancement in peak and average signal-to-noise ratio (SNR) without amplifying artifacts or introducing blurring. When used in conjunction with existing post-processing methods, e.g., total variation denoising or non-local means filtering, the proposed method yields 3-14 dB improvement in peak and average SNR. In preliminary work, we also use subspace techniques for coil combination once the interpolated k-space data are obtained using coil-by-coil reconstruction techniques such as GRAPPA.Intriguing empirical results with simulated and in vivo data show that the ad hoc technique results in images that exhibit less bias and higher contrast than the existing approaches, such as SoS. Theoretical justification and connection to principled estimation procedures remain ongoing work.The system analysis and subspace techniques developed in this dissertation provide a unified understanding of existing approaches and lead to novel techniques to meet the challenges inherent to parallel imaging.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gol Gungor, Derya
Advisor dc:contributor.advisor
  • Potter, Lee

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Gol Gungor, Derya. Subspace Techniques for Parallel Magnetic Resonance Imaging. doctoral thesis, The Ohio State University, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=osu1406301655