The Ohio State University
Ultrasound spectral parameters of micro- and nano- particles: measurement software and modeling
Abstract
dc:descriptionUltrasound tissue characterization offers information of potential diagnostic value which is unavailable to human viewers of B-mode images. Ultrasonic spectral parameters are obtained from frequency analysis of radiofrequency (RF) signals. Spectral slope (m), midband fit (M), and intercept (I) (measured in dB/Hz, dB and dB respectively) are used to characterize tissues.The objectives of this study are: to create a Graphic User Interface (GUI) for measuring ultrasonic spectral parameters, interface the software with a high frequency ultrasound (HFUS) imaging system, and compare analysis of scattering samples gathered with the software to predictions from an established model. Software was created in LabVIEW to measure spectral parameters, which also interfaced with the Vevo660 HFUS imaging system (Visualsonics, Toronto). Additional software was created to predict spectral parameters for test samples. Values for m, M and I were predicted theoretically and measured experimentally, and compared. Goodness of fit (R2) was used as a metric to judge the reliability of the experimental measurement of the three spectral parameters.Test samples were made by suspending scatterers in 1.5% agarose gel in plastic capsules. Two types of particles were used as scatterers: 1) PLA (poly lactic acid) microparticles (2.0 µm) at concentrations between 1.91E+7 and 9.57E+8 particles / ml; and 2) PS (polystyrene) particles (500 nm) at concentrations between 1.8E+10 and 1.08E+11 particles / ml.Theoretically predicted midband fits showed the best agreements with measured values when adjusted by a clumping factor (3.5 for PLA, 2.9 for PS). This factor adjusted the effective scatterer radius to account for the possible aggregation of particles during gel preparation. Predicted results for spectral slope and intercepts were also improved when the clumping factor was applied.In this study, software that enables ultrasonic data acquisition and analysis based on either bench top setups or HFUS imaging systems was successfully created. This software provides convenient interface for further studies of developing nanoparticles or microparticles as targeted ultrasound contrast agents, or in vivo tissue characterization.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2006
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Marcetich, Adam Michael
- Advisor dc:contributor.advisor
-
- Liu, Jun
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1413384380