Back to search

The Ohio State University

Control of the "Heat Island" effect on the measurements of Pyrex thin film button gauges through gauge design

Abstract

dc:description

An experimental investigation was performed to analyze the effect of non-isothermal wall temperature on the measurement of convective heat flux. The measured heat flux was inferred based on the surface temperature history from a thin film resistor (platinum) mounted on an insulator (Pyrex 7740), which was then bonded into the surface of an aluminum flat plate using epoxy as the adhesive. While this type of heat flux gauge has been used with success for over forty years, recently the accuracy of these measurements has come into question. Experimental and numerical studies have shown that the effect of the temperature discontinuity from the metal test model surface to the insulator surface disrupts the thermal boundary layer and can cause an erroneous measurement of the heat transfer coefficient. This inaccuracy of the thin film measurement device has been dubbed the “heat island” effect.To investigate this claim, tiny Pyrex thin film gauges (button gauges) were compared side by side with double sided Kapton thin film heat flux gauges (no temperature discontinuity) in a short duration fluids experiment covering a wide range of Reynolds number conditions. Important “heat island” parameters such as upstream epoxy width, epoxy type and metal temperature were varied to fully investigate the “heat island” error for comparison to theoretical correlations and numerical studies from the literature. Results show a quantifiable “heat island” effect that is smaller over the entire range of Reynolds numbers than previously reported. The upstream epoxy width / “heat island” error trend predicted by several numerical studies in the literature has been verified. A “heat island” correction correlation based on an unheated starting length solution has been shown to sufficiently bound the “heat island” error results. Ultimately, results indicate that the potential “heat island” error can be effectively controlled through button gauge design.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Murphy, James Scott
Advisor dc:contributor.advisor
  • Dunn, Michael G.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Murphy, James Scott. Control of the "Heat Island" effect on the measurements of Pyrex thin film button gauges through gauge design. masters thesis, The Ohio State University, 2004. http://rave.ohiolink.edu/etdc/view?acc_num=osu1413457982