The Ohio State University
Rapid Compositional Assessment of Tomato Fruit by Using Portable Mid-Infrared Spectroscopy.
Abstract
dc:descriptionTomatoes are consumed and cultivated all around the world. Specifically in 2012, the United States of America alone produced over 13 million tons of tomatoes. In order for the tomato to sustain its vital placement in the market, quality control poses high significance at all levels of the industry to gain the desired characteristics. Some quality traits of interest for fresh-market tomatoes can include color, ascorbic acid (vitamin C), citric acid, glucose, fructose, pH, soluble solids and titratable acidity. These attributes need to be tested through reference methods. However, the drawbacks of some reference methods include time-consuming sample preparation, use and disposal of hazardous solvents, low sample through-put, and a high skill-set for the testing personnel. Infrared spectroscopy is an ideal alternative in assessing multiple quality traits in fresh tomatoes. Mid-Infrared (FTIR) spectroscopy has become an alternative for traditional reference methods, because there is little sample preparation saving both time and money, operating the equipment is fast and simple to use, sample through-put is increased, less hazardous solvents are needed for analysis, and minimal background training is needed to operate the infrared equipment. Portable mid-infrared units are becoming popular for food manufacturers since the unit can easily be transported from laboratory, to in-plant, to in-field analysis. In fact, infrared spectroscopy has already achieved itself as a quality control tool for processed tomato products using a hot-break tomato juice sample for analysis of the quality traits. The aim of this research is to develop a rapid method for assessing quality traits of fresh-market tomatoes by collecting infrared spectra on the fruit surface at any maturity stage. Fresh-market tomatoes can be harvested at any stage of maturity (mature green, pink or red-ripe) unlike processed tomatoes that are only harvested at the red-ripe stage of maturity. Thus, it is necessary to develop fast and reliable methods that can give reliable predictions of target quality traits within the fresh-market tomato fruit before it reaches the consumer. Our objective was to develop robust prediction models based on spectra collected on the tomato fruit surface for determination of ascorbic acid, citric acid, soluble solids, pH, titratable acidity, glucose, and fructose in order to better implement portable mid-infrared units into a field setting. Additionally, spectra of single tomato juices were used to generate models to compare prediction performances against the surface readings.A total of 120 tomato samples were received from a fresh-market tomato producer throughout the 2014 summer season (June-August). The levels of acids (ascorbic and citric) and sugars (glucose and fructose), soluble solids, pH, and titratable acidity were determined using standard reference methods. For mid-infrared analysis, an attenuated total reflectance accessory equipped with a single-bounce diamond crystal was used to obtain the fruit surface spectra, while a transmittance accessory (DialPath) was used to obtain the fresh juice spectra. Partial least squares regression (PLSR) was used to generate the cross-validated, calibration models between the parameter concentrations and the sample spectra. Models based on infrared data from the tomato fruit surface did not perform as well as the fresh tomato juice models due to all of the acids and sugars not being directly introduced to the infrared beam, thus more uncertainty is incorporated into the fruit surface models. Chemometric models based on surface infrared readings predicted quality attributes with mean correlation values (R) 0.60-0.83 and prediction errors (SECV) of 0.19 for Brix, 0.1 g/100g for estimation of sugars (fructose, glucose), 0.2 units for pH and 0.1% for TA (% citric acid), and 0.05 g/100g for citric and 2.6 mg/100g for ascorbic acids while models based on juice spectra showed improved performances with correlation coefficient (RCV) ranging from 0.84-0.96 and lower standard error of cross validation (SECV) with values of 0.11 for Brix, 0.06 g/100g for estimation of sugars (fructose, glucose), 0.12 units for pH and 0.05% for TA (% citric acid), and 0.02 g/100g for citric and 1.0 mg/100g for ascorbic acids. Because the portable mid-infrared units are easy to handle and carry, the FTIR systems can provide fresh-market tomato growers and producers a rapid method to evaluate tomatoes within a laboratory setting, within a plant facility, or even in the tomato growing field.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Food Science and Technology
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Landers, Emilee Kathleen
- Advisor dc:contributor.advisor
-
- Rodriguez-Saona, Luis
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1417539506