The Ohio State University
Elastography Characterization and Repeatability in 14 Normal Canine Spleens
Abstract
dc:descriptionUltrasound is commonly used to evaluate the canine spleen. There is poor correlation between ultrasonographic findings and cytological or histopathological diagnosis. Ultrasound elastography is a relatively new technology that can measure the elasticity of tissues, and has shown usefulness in differentiating benign versus malignant conditions in the parenchymal organs in people. In animals elastography imaging is in its earliest stages of application, and has been applied mainly to musculoskeletal tissues. Only limited studies have investigated elastography characteristics of the normal canine spleen. The purpose of this study was to describe elastography characteristics of normal canine spleens and assess intra-and interobserver repeatability of the method.Elastography (Toshiba Aplio500, Elasto program) was performed by two experienced ultrasonographers in 14 clinically healthy, non-sedated dogs. Each spleen was considered normal based on B-mode ultrasound examinations. Color map images depicting the strain distribution across splenic regions of interest were recorded and were measured at minimum, neutral, and maximum transducer compression points as indicated by a simultaneously recorded applied pressure waveform. Regions of interest (ROIs) encompassing as much of the spleen as possible were drawn and pixel color percentages for each region of interest were determined. A strain score was then calculated for each spleen, using a weighted average of the percentages. Three neutral values per spleen were averaged for the first observer to see if repeatability could be improved. Elastography was repeated by the same observers using the same dogs approximately two weeks later. Statistical analysis included Friedman’s test (followed by Bonferroni-corrected signed-rank tests) to compare strain scores over the three compression points. Intra-and interobserver repeatability were assessed using Spearman’s rank-order correlation. Waveform height was evaluated to assess if differences in operator probe pressure might contribute to the data and this variable was compared between examiners by calculation of the Mann-Whitney U statistic (i.e., Wilcoxon rank-sum test). Strain scores obtained at neutral compression were significantly lower (harder) than maximum compression for both observers (P<0.05), but only observer one found a significant difference in strain score compared with minimum compression. Intraobserver correlation was moderate and statistically significant (repeatable) for observer one (Rs2 = -0.548, P=0.043), but there was marked variation among individual dogs. For observer two, there was poor to moderate correlation which was not statistically significant (Rs2 = 0.433, P=0.122), indicating poor intraobserver repeatability. Interobserver correlation for the first time point was weak to moderate but did not achieve statistical significance (Rs2 = -0.464, P=0.095), and even lower correlation was found at the second time point (Rs2 = 0.301, P=0.122). Overall these correlation coefficients indicate poor interobserver repeatability with the methods used in this study. When three neutral values per spleen were averaged for observer one, the correlation coefficient was lower but not statistically significant (Rs2 = 0.209, p=0.747). Observer two exhibited significantly more compression than observer one (P=0.002).This study demonstrates that abdominal compression influences strain scores in the canine spleen. Based on these results, we recommend obtaining strain scores at neutral compression, which is theoretically the most accurate approach and differs significantly from maximum compression. Both inter- and intraobserver repeatability were poor to moderate, findings related in part to differences in operator compression. It is likely that patient dependent factors, such as variable compliance and lack of sedation, also contributed to the less-than-ideal repeatability in this study. Accordingly, thorough training and practice as well as other standardizations are needed if this elastography technique is to become useful in canine splenic imaging in the clinical or research settings.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Comparative and Veterinary Medicine
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mulligan, Kimberly
- Advisor dc:contributor.advisor
-
- Drost, Wm Tod
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1429297879