A Study of Blockage due to Ingested Airborne Particulate in a Simulated Double-Wall Turbine Internal Cooling Passage

Abstract

dc:description

The development of flow blockage by particulate accumulation in the internal flow passages of a gas turbine double wall cooling scheme was studied experimentally. This parametric investigation focused on the effects of particle concentration, flow temperature, and particle size on the deposition characteristics in a cylindrical impingement/film cooling geometry. The impingement and film cooling hole layout is based on the leading edge cooling scheme of a modern nozzle guide vane (NGV). Tests were run at a constant pressure ratio of 1.02 (cavity pressure to exhaust) and the mass flow rate was permitted to decrease throughout the test as the cooling passages became obstructed. Particulate concentration was varied by holding the mass injected constant while adjusting the test injection time and rate. Particles consisted of Arizona Road Dust with distributions of 0-5, 0-10, and 0-20 µm. Flow blockage increased by 4% over a range of two orders of magnitude in particulate concentration for the smallest particle size distribution. At 452 °C the blockage levels increased to nearly four times that of the ambient conditions. Similar amounts of particulate deposited on the film cooling wall at ambient and high temperature, but the high temperature particulate caused greater blockage to the film holes. The effect of particle size was difficult to discern due to clumping of the smallest particles into large agglomerations. This clumping effect was coupled with the trend of increasing temperature. Implications for continued internal deposition research are discussed.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Aero/Astro Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Peterson, Blair A.
Advisor dc:contributor.advisor
  • Bons, Jeffrey

Subjects

dc:subject × 11

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Peterson, Blair A.. A Study of Blockage due to Ingested Airborne Particulate in a Simulated Double-Wall Turbine Internal Cooling Passage. masters thesis, The Ohio State University, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=osu1429738411